EasyManuals Logo

Delta VFD550VL43C-J User Manual

Delta VFD550VL43C-J
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Chapter 4 Description of Parameters | VFD-VJ
4-9
Pr. Name of Parameter Setting
Factory
Setting
VF
FOCPG
FOCPM
14: Correction of pressure feedback offset
01-08
Rated current of the
induction motor (A)
40~120% of the drive’s rated current #.##
01-09
Rated power of the
induction motor
0~655.35kW #.##
01-10
Rated speed of the
induction motor
0~65535rpm
1710 (60Hz 4-pole); 1410 (50Hz 4-pole)
1710
01-11
Number of poles of the
induction motor
2~20 4
01-12
No-load current of the
induction motor (A)
0~Default value of Pr.01-08 #.##
01-13
Stator resistance (Rs) of
the induction motor
0~65.535
0
01-14
Rotor resistance (Rr) of
the induction motor
0~65.535
0
01-15
Magnetizing inductance
(Lm) of the induction
motor
0.0~6553.5mH 0
01-16
Total leakage inductance
(Lx) of the induction
motor
0.0~6553.5mH
0
01-17
Rated current of the
synchronous motor
0.00~655.35 Amps We’ve
set up
Pr.01-17
to
Pr.01-24
of each
hybrid
servo
drive
before
shipping
them to
you.
01-18
Rated power of the
synchronous motor
0.00~655.35kW
01-19
Rated speed of the
synchronous motor
0~65535rpm
01-20
Number of poles of the
synchronous motor
2~20
01-21
Inertia of the
synchronous
motor’s rotor
0.0~6553.5 *10
-4
kg.m
2
01-22
Stator’s phase resistance
(Rs) of the synchronous
motor
0.000~65.535

Table of Contents