Chapter 12 Description of Parameter SettingsC2000-HS
12.1-04-4
Multi-step position corresponding MI4 MI3 MI2 MI1 Multi-step speed corresponding
04-22 Position command 4 (pulse) 0 1 0 0 04-03 4
th
step speed frequency
04-24 Position command 5 (pulse) 0 1 0 1 04-04 5
th
step speed frequency
04-26 Position command 6 (pulse) 0 1 1 0 04-05 6
th
step speed frequency
04-28 Position command 7 (pulse) 0 1 1 1 04-06 7
th
step speed frequency
04-30 Position command 8 (pulse) 1 0 0 0 04-07 8
th
step speed frequency
04-32 Position command 9 (pulse) 1 0 0 1 04-08 9
th
step speed frequency
04-34 Position command 10 (pulse) 1 0 1 0 04-09 10
th
step speed frequency
04-36 Position command 11 (pulse) 1 0 1 1 04-10 11
th
step speed frequency
04-38 Position command 12 (pulse) 1 1 0 0 04-11 12
th
step speed frequency
04-40 Position command 13 (pulse) 1 1 0 1 04-12 13
th
step speed frequency
04-42 Position command 14 (pulse) 1 1 1 0 04-13 14
th
step speed frequency
04-44 Position command 15 (pulse) 1 1 1 1 04-14 15
th
step speed frequency
PLC Buffer 0
PLC Buffer 1
PLC Buffer 2
PLC Buffer 3
PLC Buffer 4
PLC Buffer 5
PLC Buffer 6
PLC Buffer 7
PLC Buffer 8
PLC Buffer 9
PLC Buffer 10
PLC Buffer 11
PLC Buffer 12
PLC Buffer 13
PLC Buffer 14
PLC Buffer 15
PLC Buffer 16
PLC Buffer 17
PLC Buffer 18
PLC Buffer 19
Default: 0
Settings 0–65535
You can combine the PLC buffer with the built-in PLC function for a variety of applications.