Chapter 12 Descriptions of Parameter SettingsMS300 
347 
 
 Set up Pr.01-35 and Pr.05-15 before setting up Pr.05-16 to ensure that the motor operates 
normally. 
No-load Current for Induction Motor 2 (A) 
Default: Depending on the 
model power 
 The default is 40% of the motor's rated current. 
Stator Resistance (Rs) for Induction Motor 2 
Default: Depending on the 
model power 
Rotor Resistance (Rr) for Induction Motor 2 
Magnetizing Inductance (Lm) for Induction Motor 2 
Stator Inductance (Lx) for Induction Motor 2 
Multi-Motor (Induction) Selection 
3: Motor 3 (VF or SVC control mode only) 
4: Motor 4 (VF or SVC control mode only) 
 Sets the motor operated by the AC motor drive. Multi-motor selection only supports single 
control mode. For example, when you set motor 1 as SVC control mode, the control mode of 
motors 2–4 are also set as SVC.
Frequency for Y-connection /-connection Switch for an Induction Motor 
Y-connection /-connection Switch for an Induction Motor 
Delay Time for Y-connection/-connection Switch for an Induction Motor 
 You can apply Pr.05-23–Pr.05-25 in wide range motors, and the motor coil executes the Y-
connection/-connection switch as required. The wide range motors are related to the motor 
design. In general, the motor has higher torque with low speed Y-connection and has higher