Do you have a question about the Delta VFD9A0ME43ANNAA and is the answer not in the manual?
Model | VFD9A0ME43ANNAA |
---|---|
Rated Output Current | 9 A |
Horsepower | 5 HP |
Amperage | 9 A |
Protection Level | IP20 |
Phase | 3 |
Control Method | V/F Control, Sensorless Vector Control |
Frequency Range | 0.1-400Hz |
Detailed dimensions (W, H, D, W1, H1, D1, S1) for Frame A AC motor drives, with specifications in mm and inches.
Detailed dimensions (W, H, D, W1, H1, D1, S1) for Frame B AC motor drives, with specifications in mm and inches.
Detailed dimensions (W, H, D, W1, H1, D1, S1) for Frame C AC motor drives, with specifications in mm and inches.
Detailed dimensions (W, H, D, W1, H1, D1, S1) for Frame D AC motor drives, with specifications in mm and inches.
Diagram illustrating the system wiring for AC motor drives, including power input, NFB, contactor, reactors, and output terminals.
Detailed wiring instructions and precautions for AC motor drives, covering input power, output terminals, and control terminals.
Diagram showing the main circuit connections for AC motor drives, including terminals for power, DC reactor, brake resistor, and motor.
Selection guide for brake resistors and brake units, including applicable models, specifications, and braking torque.
Details on protection parameters such as low voltage, over-voltage, over-current stall prevention, and over-torque detection.
Parameters for high-function PID control, including terminal selection, gains, filter times, and deviation settings.
Parameters related to communication settings, including address, transmission speed, fault treatment, protocol, and data format.
Parameters for speed feedback control, covering pulse input type, frequency deviation, current command, and sensorless speed estimation.
Parameters for various functions, including set point deviation, liquid leakage detection, multi-pump control, and simple positioning.
Additional protection parameters, including output frequency, DC voltage, output current, and IGBT temperature at malfunction.
List of warning codes displayed on the LCM keypad, including warning name, description, action level, and corrective actions.
Detailed descriptions of fault codes, including display on LCM keypad, fault name, description, action/reset, cause, and corrective actions.
Overview of the Safe Torque Off (STO) function, its dual-channel signal inputs, and compliance with international safety standards.
Description of STO related terminal functions, including +24V, S1, S2, DCM signals, and action logic tables.
Description of STO, STL1, STL2, STL3 error codes and related troubleshooting instructions for digital keypad displays.
Step-by-step verification procedures to confirm the normal working of STO and related detection functions.