I‐1083 Page2of4
Rev.A‐40009 8/6/14
IMPORTANT,SINGLEFILLUNITS
ONLY:Insert/changeouttheright
meteringtiponly.Therightsideis
correctlyidentifiedasthewater
supplyswivelfacingyou,shown
here.
MeteringTipInstallation:
Meteringtipsaredesignedtometeryourchemicalsatadesireddilutionratio.Pleaserefertothe
MeteringTipguide(tablebelow)

SingleorDual  Single Dual  Single Dual  Single Dual
ModelNo.
(Selector
position(dual):
LorR)

DM1S.1
DM1SGAP.1
DM1D.1,3,4(L)
DM1DGAP.1,3,4(L)

DM1S.2
DM1SGAP.2
DM1D.2(L&R)
DM1DGAP.2(L&R)
DM1DS.2&4(R)
DM1DS.1&3(L&R)

DM1S.3
DM1SGAP.3
DM1SS.1
DM1SS.2
DM1D.1,3,4(R)
DM1DGAP.1,3,4(R)
FlowRate
Low(1GPM) Med(2.8GPM) High(4GPM)
TipColor  Ratio:1 OZ/GAL ml/L  Ratio:1 OZ/GAL ml/L  Ratio:1 OZ/GAL ml/L
Tan
157 0.82 6.41 269 0.48 3.75 296 0.43
3.36
Orange
95 1.35 10.55 187 0.69 5.39 245 0.52
4.06
Turquoise
84 1.53 11.95 158 0.81 6.33 242 0.53
4.14
Pink
48 2.66 20.78 106 1.20 9.37 160 0.80
6.25
LightBlue
38 3.35 26.17 85 1.50 11.72 128 1.00
7.81
Brown
33 3.88 30.31 88 1.45 11.33 118 1.09
8.52
Red
28 4.50 35.15 68 1.87 14.61 95 1.35
10.55
White
24 5.25 41.01 58 2.21 17.26 82 1.56
12.19
Green
21 6.14 47.97 54 2.37 18.51 74 1.73
13.51
Blue
16 8.02 62.65 41 3.14 24.53 57 2.25
17.58
Yellow
11 11.76 91.87 27 4.79 37.42 38 3.41
26.64
Black
9 14.11 110.23 21 6.04 47.18 28 4.59
35.86
Purple
5 26.37 206.00 12 10.91 85.23 17 7.75
60.54
Gray
4.5 28.27 220.85 10 12.56 98.12 14 9.21
71.95
None  3.6 35.00 273.42  5.8 22.07 172.41  8 16.25
126.95
1. Removethecenterhousingcoverbyremovingthetwo
Phillipsheadscrewsasshown.
2. Removescrewsfromthemeteringcompartmentand
carefullyprymeteringtipholderofftheDM1unit.There
aretwometeringtipholders.Fordualfillunits,bothleft
andrightmeteringtipholdersareused.Forsinglefill
unitsonlytherightmeteringtipholderisused.Remove
oneorbothasapplicable.
3. Taketheidentifiedmeteringtipandthreaditintothemeteringtipholder.
4. ReplacethemeteringtipholderbackintotheDM1unit.Alignthemeteringtipholderwith
thescrewholes.Insertscrewsandtightenbackintounit.

Themeteringtipis
insertedintothemeter
tiphousing,shownhere.