Note: When Encrypt Password mode is enabled, the Multiple Access option is
not taken into account and, at any given moment, only one user can be logged-in.
Note: When Multiple Access mode is enabled, any XML/JSON request will
always reset the current HTTP session.
Note: When Multiple Access mode is disabled, whether Encrypt Password is
enabled or not, it is possible to access the module via XML/JSON only after login for
the specified session timeout.
You have to reboot the device for these settings to apply.
It is highly recommended to log out from the web server after finishing the
parameters setup.
If you don‟t want to restrict the HTTP/XML/JSON access by IP address,
set the Access Mask to 0.0.0.0.
If you don‟t want to restrict the HTTP/XML/JSON access by MAC address,
set the MAC Address to 00:00:00:00:00:00.
Setting the Access Mask to 255.255.255.255 allows the HTTP/XML/JSON
access only from the exactly specified Access IP Address.
You can allow the HTTP/XML/JSON access to a range of IP addresses by
setting an appropriate value for Access Mask. For example setting the
Access IP Address to 192.168.1.0 and Access Mask to 255.255.255.0
allows the access from IP addresses in range from 192.168.1.0 to
192.168.1.255.