EasyManua.ls Logo

Dennerle CarboPOWER E400 - Special Information

Dennerle CarboPOWER E400
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
6.4 Replacing the CO special indicator
In order to ensure the fastest and most accurate colour reaction, we recommend filling the test container every 4-6 weeks with
fresh CO special indicator fluid. You can pour used indicator fluid down the drain in your home.
6.5 Cleaning the CO long-term test
Use warm water and soft sponge. Do not use cleaning agents.
6.6 Special information
The CO special indicator is safe and free of chemical solvents. Nevertheless avoid prolonged skin and eye contact.
Indicator liquid that accidentally enters the aquarium is harmless for all aquarium inhabitants.
Store indicator liquid away from sunlight, heat and frost. Always store ampoules in a place that is not exposed to direct
light. Filling level due to technical reasons.
6.7 If you want to know more: How to determine the CO content in the aquarium
CO concentration, carbonate hardness (KH) and pH are in a certain ratio to one another. The CO concentration of the water
can be calculated from the pH and carbonate hardness. Suitable pH and KH tests can be obtained from specialist retailers.
Measure the carbonate hardness of the aquarium water.
In the table, read the corresponding pH value for the desired CO concentration. You should adjust the pH +/- 0.1 by
appropriately regulating the bubble count.
Example: Carbonate hardness 4 °d, desired CO content 20 mg/l = recommended pH 6.8
too much CO CO correct too little CO
pH
KH 6,3 6,4 6,5 6,6 6,7 6,8 6,9 7,0 7,1 7,2 7,3 7,4 7,5
2 32 25 20 16 13 10 8 6 5 4 3 3 2
3 48 38 30 24 19 15 12 10 8 6 5 4 3
4 64 51 40 32 25 20 16 13 10 7 6 5 4
5 80 63 50 40 32 25 20 16 13 10 8 6 5
6 96 76 60 48 38 30 24 19 15 12 10 8 6
7 111 89 70 56 44 35 28 22 18 14 11 9 7
8 127 101 80 64 51 40 32 25 20 16 13 10 8
9 143 114 90 72 57 45 36 29 23 18 14 11 9
10 159 126 100 80 63 50 40 32 25 20 16 13 10
11 175 139 111 88 70 55 44 35 28 22 18 14 11
12 191 152 121 96 76 60 48 38 30 24 19 15 12
13 207 164 131 104 82 65 52 41 33 26 21 16 13
14 223 177 141 112 89 70 56 44 35 28 22 18 14
CO concentration in mg/l
7 Care and maintenance
7.1 Replacing disposable CO bottle
The pressure reducer can be unscrewed at any time – the bottle valve closes automatically.
Screw the pressure reducer onto a new CO disposable bottle (see 4.1).

Related product manuals