23
AVR-4310CI/AVR-4310/AVC-4310
5F
Invalid data in firmware such as
Sub CPU, DSP, FPGA, and PLD
for rewriting sent from DM860
(invalid data received).
Turn the power off then back on.
Updating starts  automatically.
60
NACK received when āPā com-
mand sent to Sub CPU, DSP,
FPGA, PLD etc.
Turn the power off then back on.
Updating starts  automatically.
61
NACK received when āIā command
sent to Sub CPU, DSP, FPGA,
PLD etc.
Turn the power off then back on.
Updating starts  automatically.
80
Failure to acquire serial flash data
and before deleting serial flash.
Turn the power off then back on.
Updating starts  automatically.
81
Failure to delete data before rewrit-
ing serial flash.
Turn the power off then back on.
Updating starts  automatically.
82
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when timed out).
Turn the power off then back on.
Updating starts  automatically.
83
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when an error).
Turn the power off then back on.
Updating starts  automatically.
84
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when a Check Sum error).
Turn the power off then back on.
Updating starts  automatically.
85
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when invalid data
received).
Turn the power off then back on.
Updating starts  automatically.
86
Failure to rewrite when writing data
in serial flash.
Turn the power off then back on.
Updating starts  automatically.
A0
Failure to acquire (Application
Mode) IP address before rewriting
DM860 (AutoIP).
Check the network  connection.
Carry out the update in an environment
that has little network load.
A1
Failure to acquire (Application
Mode) IP address before rewriting
DM860 (when timed out).
Check the network  connection.
Carry out the update in an environment
that has little network load.
A2
Notification of invalid login via
DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network  connection.
Carry out the update in an environment
that has little network load.
A3
Notification of line congestion via
DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network  connection.
Carry out the update in an environment
that has little network load.
A4
Notification of connection failure
via DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network  connection.
Carry out the update in an environment
that has little network load.
Error 
code
Details of Error code Display Coping strategies
S
ub
***
mi n
U
pda t i ng f a i l 5F
S
ub
***
mi n
U
pda t i ng f a i l 60
S
ub
***
mi n
U
pda t eCheckNG 61
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 80
***
mi n
U
pda t i ng f a i l 81
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 82
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 83
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 84
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 85
G
UI Fl ash
***
mi n
U
pda t i ng f a i l 86
G
UI Fl ash
E
ther IMG
***
mi n
C
onnec t i onFa i l A0
E
ther IMG
***
mi n
C
onnec t i onFa i l A1
E
ther IMG
***
mi n
L
og i n f a i l ed A2
E
ther IMG
***
mi n
S
erver is busyA3
E
ther IMG
***
mi n
C
onnec t i onFa i l A4