ADJUSTING
THE
ELECTRICAL
SECTIONS
e
Measuring
instruments
necessary
for
adjustments
(1)
Audio
signal
generator
(2)
Variable
resistance
attenuator
(3)
Vacuum
tube
voltmeter
(4)
Oscilloscope
(5)
Frequency
counter
(6)
Adjustment
screwdriver
(7)
Trap
coil
adjustment
square
stick
(8)
Test
tapes
(TEAC
MTT-111,
MTT-114,
MTT-150,
MTT-316
or
116K)
(MAXELL
XL-11)
C-46
or
C-60
(DENON
DX
3,
DXM)
(COLUMBIA
LX-C60)
(9)
Transport
check
cassette
tape
(COLUMBIA
C-120,
modified)
*
Cautions
on
adjusting
(1)
Before
adjusting,
clean
the
head
surface,
capstan
and
the
pinch
roller
with
a
gauze
or
a
cotton
swab
moisten-
ed
with
alcohol.
(2)
Demagnetize
the
R/P
HEAD
and
the
E.HEAD
with
a
head
eraser.
(3)
Completely
demagnetize
the
adjustment
screwdriver.
(4)
Unless
instructed
otherwise,
set
the
various
controls
as
follows:
INPUT
volume...
„sun.
maximum
clockwise
OUTPUT
LEVEL
volume
. .
maximum
clockwise
DOLBY
NRswitch.......
OFF
TAPE
SELECT
switch.....
CrO,
MONITOR
switch........
TAPE
1.
Tape
Transport
Check
Load
the
transport
check
cassette.
In
the
operational
mode,
illuminate
the
fixing
guides
of
the
R/P
HEAD
with
a
lamp
and
check
to
make
sure
the
tape
edge
does
not
come
in
contact
with
the
tape
guide
section.
The
tape
transport
is
the
most
important
element
in
de-
terming
the
performance
of
a
cassette
deck.
Avoid
moving
the
various
adjustment
screws,
nuts,
etc.,
as
much
as
possible.
Refer
to
the
pages
on
“Adjusting
and
Checking
the
Mechanism
Section”
when
replacing
or
adjust-
ing
the
R/P
HEAD.
2.
Adjusting
the
Azimuth
(1)
After
completing
the
tape
transport
check,
load
the
test
tape
(TEAC
MTT-114).
Play
back
the
test
tape;
adjust
the
azimuth
screw
so
that
section
A
of
the
resurge
wave
form
is
maximum
and
section
B
is
minimum.
(2
3.
Checking
and
Adjusting
the
Tape
Speed
(1)
(DR-F6/F7)
(2
(1
(2
=16=
)
1)
Connect
the
frequency
counter
to
the
LINE
OUT
terminal
and
load
the
test
tape
(TEAC
MTT-111).
F
Counter
PB
Amp
LINE
OUT
3000
3000
Hz
26Η:
MTT-
2)
Play
back
the
test
tape;
at
the
midpoint
of
the
tape,
where
the
transport
is
stable,
adjust
VR
1
of
KU-0426
(DD
MOTOR
UNIT)
so
that
the
fre-
quency
counter
reading
is
in
the
range
of
3,000
Hz
+
61.
(DR-F8)
1)
Adjusting
the
lock
position
Measure
the
T.P.
of
KU-0434
(QUARTZ
LOCK
UNIT)
with
the
oscilloscope
and
adjust
VR
1
of
KU-0426
(DD
MOTOR
UNIT)
so
that
the
duty
is
50%
(906
Hz)
_
At
this
time,
LE
901
(red
LED)
of
KU-0434
will
light
up.
2)
Connect
the
frequency
counter
to
the
LINE
OUT
terminal
and
play
back
the
test
tape
(TEAC
MTT-111).
Check
to
make
sure
the
frequency
counter
reading
is
in
the
range
of
3,000
Hz
+
6
Hz.
Adjusting
the
Input
Sensitivity
Set
the
MONITOR
switch
to
SOURCE
position,
the
operational
mode
at
STOP.
Supply
a
400
Hz
signal
using
audio
signal
generator
to
the
LINE
IN
terminal
and
set
the
input
signal
level
(approx.
—18
dB)
so
that
the
output
level
at
the
test
point
TP
51
(L
ch)
on
the
Dolby
circuit
board
becomes
—2.5
dB.
Adjust
Vr
301
on
the
audio
circuit
board
so
that
the
output
level
at
the
test
point
TP
61
(R
ch)
on
the
Dolby
circuit
board
becomes
—2.5
dB.
In
the
case
of
DR-F6,
adjust
Vr
204.
DOLBY
Amp
LINE
IN