www.desatech.com
111986-01F32
-


    
(see Replacement Parts 
     
    



-


If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door, page 24). Vacuum all glass pieces with
a shop vac.
CAUTION: Do not vacuum if

Use only the tempered glass door replacement
intended for this replace (see Replacement
Parts, page 37, for detail on ordering). No
substitutions may be made. See Removing/
Replacing Glass Door, page 24, for instructions
for replacing glass door.
  
    


Remove ember material before cleaning
burners and replace when cleaning is
complete.
Burner and controls should be cleaned
with compressed air to remove dust, dirt,
or lint.
Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt, or lint.
CLEANING AND
MAINTENANCE
Continued
LOGS
If you remove logs for cleaning, refer to
Installing Logs, Lava Rock, and Glowing
Embers, page 25, to properly replace
logs.
Use a vacuum cleaner to remove any
carbon buildup on logs.
Replace log(s) if broken. See Replacement
Parts on page 37.
Replace ember material periodically as needed.
See Replacement Parts on page 37.

Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualied service person.
2. Remove the vent cap and shine a ash-
light into the vent. Remove any foreign
material.
3. Check for evidence of excessive con-
densation. Continuous condensation
can cause corrosion of caps, pipes, and
fittings and can be caused by having
excessive lateral runs, too many elbows,
or exterior portions of the system being
exposed to cold weather.
4. Inspect joints to verify that no pipe section
or tting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.