111986-01F28
4. Push in gas control knob slightly and turn
clockwise to OFF.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information in column 1. If
you don’t smell gas, go to the next step.
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT.
8. Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
pressing piezo spark ignitor until a ame ap-
pears. Continue to hold for about 1 minute
after pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit.
If it goes out, repeat steps 4 through 7.
If gas control knob does not pop up when
released, stop and immediately call our
service technician or gas supplier.
If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to replace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set replace input as desired.
12. To leave pilot lit and shut off burners only,
turn control knob clockwise to the
PILOT position then set selector switch in
the OFF position.
13. Close lower louver panel.
OPERATION
FOR YOUR SAFETY

WARNING: If you do not fol-
low these instructions exactly,
     
-

 -


     




WHAT TO DO IF YOU SMELL GAS



    


 

 



     





LIGHTING
INSTRUCTIONS



-



1. STOP! Read the safety information,
above.
2. Open lower louver panel.
3. Turn off all electric power to replace.
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to the appli-
ance if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise to OFF.
5. Close lower louver panel.
6. Close equipment shutoff valve (see
Figure 33, page 22).
O
F
F
P
I
L
O
T
L
O
I
H
O
N
Figure 52 - Control Valve
Piezo
Ignitor
Gas Control
Knob
Variable Control Knob