www.desatech.com
111986-01F36
TROUbLESHOOTING
Continued
-
Fireplace produces unwanted
odors
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside
of replace
1. Gas leak.
1. Gas leak.
2. Control valve defective
1. Gas leak.
1. Improper log placement
2. Air holes at burner inlet
blocked
3. Burner ame holes blocked
4. Improper venting or exces-
sive blockage
5. Excessive amounts of em-
bers and pan material
REMEDY
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 21)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 21)
2. Replace control valve
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 21)
1.
Properly locate logs (see In-
stalling Logs, Lava Rock, and
Glowing Embers, page 25)
2. Clean out air holes at burner
inlets. Periodically repeat as
needed
3. Remove blockage
4. Have the vent system in-
spected, including the ter-
mination cap. Remove any
restrictions or obstruction
5. Clear excess embers until
a minimum gap of 1/2" re-
mains under the grate