LBB Series Oven Owners Manual ABOUT THIS MANUAL
Version 20 13
1.5.3. Power
If the line voltage for your LBB Series oven varies more than 10% from the oven voltage rating,
electrical components such as relays and temperature controls may operate erratically.
If the line voltage is lower than the oven voltage rating, heat-up time may be significantly
longer and motors may overload or run hot.
If the line voltage is higher than the nameplate rating, motors may run hot and draw excessive
amperage.
Model
Volts
Amps
Hertz
Phase
Heater
KW
Cord and Plug
LBB 1-23
120
11.6
50/60
1
1.2
Included, 15 Amp
LBB 1-23
240
5.8
50/60
1
1.2
Included, 15 Amp
LBB 1-69*
120
21.6
50/60
1
2.4
None, Hardwired
LBB 1-69*
240
10.8
50/60
1
2.4
None, Hardwired
LBB 2-12*
240
16.6
50/60
1
3.6
None, Hardwired
LBB 2-18*
240
16.7
50/60
1
3.6
None, Hardwired
LBB2-27*
240
21.7
50/60
1
4.8
None, Hardwired
* Models LBB1-69, LBB2-12, -18 and -27 must be hardwired to the electric supply using 10 AWG or
larger wire suitable for at least 75 °C (167 °F).
Ovens designed for 240 volts (check your oven nameplate for power
requirement) will operate satisfactorily on a minimum of 208 volts, but
with a 25% reduction in heater power. If your power characteristics are
lower, contact Despatch industries.