D-1 95-86763.1
APPENDIX D
INMETRO APPROVAL
UL-BR 15.0242X
Ex d [ib] IIC T4-T5 Gb IP66/67
T5 (T
amb
–55°C to +40°C)
T4 (T
amb
–55°C to +75°C)
––OR––
Ex d e [ib] IIC T4-T5 Gb IP66/67
T5 (T
amb
–50°C to +40°C)
T4 (T
amb
–50°C to +75°C)
NOTE
All cable entry devices and blanking elements shall be Brazil certied in the type of explosion protection,
ameproof enclosure ‘d’, suitable for the conditions of use and correctly installed, with an ingress protection
rating of IP66/IP67. A screw or cover lock is provided for a secondary means of fastening the cover.