17
V75
Fault code Reason Solution
Problem with the left count sensor error or the
relative circuit.
1. Poor contact of the emitter tube, re-plugging.
4. Check the circuit connection.
2. Poor contact of the receiving tube, re-plugging. 5. Replace the main board.
3. Replace the right counting sensor.
Problem with the right count sensor error or the
relative circuit.
1. Poor contact of the emitter tube, re-plugging. 4. Check the circuit connection.
2. Poor contact of the receiving tube, re-plugging. 5. Replace the main board.
3. Replace the right counting sensor.
Something or dust covered the banknote
receiving sensor.
1. Remove all things in the stacker
3. Check the circuit
and clean the sensor. connection.
2. Replace the reset sensor or plug well.
4. Replace the main board.
Problem with the reset sensor.
1. Problem with the main motor error.
1. Replace the main motor. 4. Check the circuit connection.
2. Replace the driving belt. 5. Replace the main board.
2. Problem with the driving belt error.
3. Replace the speed sensor or plug well.
3. Problem with spend(dial)sensor.
Judge the feeding sensor error or not.
Cover the sensor then turn on the machine, if the display show”EA4” means the
sensor is in good working condition, otherwise the feeding sensor or the connect
circuit fault.
8. Fault code and solution