6
High-pressure pump
TCD 2013 2V W 17-01-01
Removing and installing the control block
Standard tools
Special tools:
Plugs/caps 170160
User notes
Operation manual
Danger!
Wait 30 seconds after switching off the
engine before working on the fuel system.
Attention!
Ensure utmost cleanliness when working
on the fuel system.
Carefully clean the area around the
affected parts. Blow damp areas dry with
compressed air.
Observe the safety regulations and natio
-
nal specifications for handling fuels.
Close all connections immediately after
opening with new, clean plugs/caps.
Do not remove plugs/caps until immedia
-
tely before assembling.
Collect leaking operating fluids in suitable
vessels and dispose of according to regu
-
lations.
After all work on the fuel system, it must be
bleeded - see the operation manual, chap
-
ter "6 Fuel system“.
Removing the control block
Unlock cable plug (1) and remove.
Danger!
Wait 30 seconds after switching off the
engine before working on the fuel system.