3 Settings
How to change the minimum and maximum floor tem-
peratures
1. Remove the adjust-
ment button.
2.
Move the pins to the
desired positions.
3. Put the adjustment
button back in place.
devireg™550
20
30
40
50
20
30
35
15
25
Note Please be aware of the following:
The floor temperature is measured where the floor
sensor is placed.
The temperature of the bottom of a wooden floor can
be up to 10 degrees higher than the top.
Floor manufactures often specify the max temperature
on the top surface of the floor (usually 27-28˚C).
By default, the maximum floor temperature is set to
35°C.
Always use a floor sensor or a room + floor sensor
combination to control floor heating. Without a floor
sensor, the temperature control may be less accurate
and you risk overheating the floor.