Technical Data
Temperature range: +5
0
C to +45
0
C
Voltage: 180 – 250 V ~ 50 Hz
Load: Cos φ =0.3 max. 2 A
Breaking capacity
terminals 2 and 5:
10 A 250 V ~
Breaking capacity
terminals 1 and 2:
16 A 250 V ~
Hysteresis: 0.5
0
C
Night set-back: 5
0
C
Operating temperature: -10
0
C to +50
0
C
Moisture proof: IP 20
Sensing unit: NTC 15 kOhm at 25
0
C
Sensing values:
-10
0
C 66 kOhm
0
0
C 42 kOhm
+25
0
C 15 kOhm
+50
0
C 6 kOhm
LED Indicator:
No Light
Red
Green
The System is OFF.
The Heating is ON but
the preset temperature
has not been reached.
The preset
temperature has been
reached and Heating is
OFF.