The sensor is to be considered as live voltage. Have
this in mind if the sensor must be extended.
Always connect the thermostat to continuous power
supply.
Do not expose the thermostat to moisture, water, dust,
and excessive heat.
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on
the wall (typically 80-170cm.).
In wet rooms, place the thermostat according
to local regulation on IP classes.
Note: A floor sensor enables a more accurate
temperature control and is recommended in
all floor heating applications and mandatory
under wooden floors to reduce the risk of
over-heating the floor.
DEVIreg™ 528
6 Installation Guide