9. Technical specications for Devireg™ 530, 531, and 532
Operation voltage 240 VAC +10/ -20, 50 Hz
Power consumption Max. 0.25W
Relays:
Resistive load
Inductive load
240V ~ 15A
cos φ = 0.3 Max. 4A
Sensing unit NTC 15 kOhm at 25°C
Sensing values:
• 0°C
• 20°C
• 50°C
42 kOhm
18 kOhm
6 kOhm
Hysteresis +/- 0.2°C
Ambient temperature -10° to +30°C
Frost protection 5°C