Setting up your Devireg 535 programmable thermostat with
your devimat system
Devireg 535
Selection of sensor type
Power on the thermostat
With the front o, with
a small screwdriver
or pencil press the
installation button.
Select the oor sensor
To change the default setting, press
l and use the arrow buttons  to
select your choices. Press l to accept
your choice.
Press for the next setting.
Maximum oor temperature.
- Tiles on timber based oor = 29°C
- Tiles on concrete based oor = 40°C
- Timber covered oors = 27°C
(parquet etc. - Please check with
oor supplier).
To change this setting, press l and
use the arrow buttons  to select
your choice. Press l to accept your
choice.
Press for the next setting.
Scale
When selecting Celsius, the display
will show the actual temperature at
the oor sensor.
To change this setting, press l and
use the arrow buttons  to select
your choice.
Press l to accept your choice.
The installation procedure is now nished.
You can use the  for going back or forward through
the settings, otherwise:
Press the installation pinhole to exit
installation mode.
Put the frame and front back on.
You enter the settings by pressing the
pinhole with a small screw driver,
pencil, the display now changes from
temperature to time display.
By pressing the l, the hours starts
ashing - you can now change them
with the .
Press the l again to change the
minutes with the .
To nish, press l then
Setting the time
Setting the weekday
Mon Tue Wed Thu Fri Sat Sun
By pressing the l, the weekday starts
ashing - you can now change them
with the .
Press the l to accept.
To nish press