0044
EN
DeVilbiss® 5-Liter Oxygen Concentrator
Instruction Guide
WARNING–Read instruction guide before operating this equipment.
ASSEMBLED IN USA
NO SMOKING
ES
Guía de instrucciones del concentrador de
oxígeno de 5-litros de DeVilbiss®
ADVERTENCIA–Lea la guía de instrucciones antes de poner a funcionar este equipo.
ENSAMBLADO EN EE. UU.
NO FUMAR
FR
Guide d’instructions du concentrateur
d’oxygène 5-litres DeVilbiss®
AVERTISSEMENT–Lire le mode d’emploi avant d’utiliser ce dispositif.
ASSEMBLÉ AUX ÉTATS-UNIS
NE PAS FUMER
DE
DeVilbiss® 5-Liter-Sauerstoffkonzentrator
Bedienungsanleitung
WARNUNG–Vor Inbetriebnahme des Gerätes Bedienungshinweise lesen.
HERGESTELLT IN DEN USA
RAUCHEN VERBOTEN
IT
Concentratore di ossigeno da 5-litri
DeVilbiss® Istruzioni per l’uso
AVVERTENZA–Leggere il manuale di istruzioni prima di usarel’apparecchio
ASSEMBLATO NEGLI U.S.A.
NON FUMARE
NL
Instructiehandleiding DeVilbiss® 5-liter
zuurstofconcentrator
WAARSCHUWING–Lees dit instructiehandboekje zorgvuldig door voordat u het
apparaat gaat gebruiken.
GEMONTEERD IN DE VERENIGDE STATEN
VERBODEN TE ROKEN
TR
DeVilbiss® 5-Litre Oksijen Konsantratörü
Kullanım Kılavuzu
UYARI–Cihazı kullanmaya başlamadan önce bu kılavuzu okuyunuz.
ABD’DE MONTE EDILMIŞTIR
SİGARA İÇİLMEZ
PT
Manual de instruções do Concentrador de
oxigênio DeVilbiss® de 5-litros
ADVERTÊNCIA– Leia o manual de instruções antes de operar este equipamento.
MONTADOS NOS EUA
PROIBIDO FUMAR
PL
Instrukcja obsługi 5-litrowego
koncentratora tlenu DeVilbiss®
OSTRZEŻENIE – LPrzeczytaj instrukcję obsługi przed rozpoczęciem korzystania z tego
urządzenia.
ZMONTOWANO W STANACH ZJEDNOCZONYCH
NIE PALIĆ

AR
5®DeVilbiss





525 Series
Serie de 525
Série 525
525 Serie
Serie da 525
525 Serie
525 Serisi
Série 525
Seria 525
525 

Table of Contents

Other manuals for DeVilbiss 525DS-Q

Questions and Answers

  • A
    ashleypooleAug 4, 2025
    What to do if DeVilbiss Medical Equipment unit does not operate?
    • M
      Michelle SawyerAug 4, 2025
      If the DeVilbiss Medical Equipment unit isn't operating, all lights are off, and an audible alert is pulsing, first ensure the power cord is properly inserted into the wall outlet. For 230-volt units, check the mains connection on the back. If it still doesn't work, check your home circuit breaker and reset it if needed. If problems persist, try a different wall outlet. Also, check the oxygen concentrator circuit breaker and reset it if necessary by pressing the reset button located below the power switch. If these steps don't resolve the issue, contact your DeVilbiss provider.
  • J
    Joseph ValenzuelaAug 9, 2025
    What to do if red service required light is on DeVilbiss Medical Equipment?
    • C
      Carmen HollandAug 9, 2025
      If the red Service Required light is illuminated on your DeVilbiss Medical Equipment and an audible alert is sounding, check the following: * **Air filter:** If it's dirty, clean it according to the instructions. * **Exhaust area:** Ensure nothing is blocking the unit's exhaust. * **Cannula, mask, or tubing:** Detach these to see if proper flow returns. If it does, clean or replace the blocked component. * **Humidifier bottle:** Detach to check if flow improves; clean or replace if needed. * **Flow meter:** Ensure it's set to the prescribed rate. If issues persist, contact your DeVilbiss provider.
  • A
    Alan BaldwinAug 13, 2025
    Why is the yellow low oxygen light on DeVilbiss Medical Equipment?
    • G
      gmosesAug 13, 2025
      If the yellow Low Oxygen light is on your DeVilbiss Medical Equipment, allow the unit up to 15 minutes to complete its start-up period.
  • S
    Sarah HolmesAug 17, 2025
    What to do if yellow low oxygen light is on and intermittent audible signal is sounding on DeVilbiss Medical Equipment?
    • M
      Mario Martin PhDAug 17, 2025
      If the yellow Low Oxygen light is on and an intermittent audible signal is sounding on your DeVilbiss Medical Equipment, make sure the flow meter is properly set to the prescribed number. Note that the maximum flow meter setting is 3 LPM when filling an oxygen bottle from the auxiliary port. Also, check the air filter and clean it if it's dirty. Finally, check the exhaust area to ensure nothing is blocking the unit's exhaust. If these steps don't resolve the issue, contact your DeVilbiss provider.
  • S
    Sean JimenezAug 22, 2025
    What to do if red service required light is on and intermittent audible signal is sounding on DeVilbiss Medical Equipment?
    • A
      angelicamitchellAug 22, 2025
      If the red Service Required light is on and an intermittent audible signal is sounding on your DeVilbiss Medical Equipment, ensure the flow meter is properly set to the prescribed number, noting that the maximum flow meter setting is 3 LPM when filling an oxygen bottle from the auxiliary port. Check the air filter and clean it if needed. Also, check the exhaust area to ensure it's not blocked. If these steps don't resolve the issue, or if you suspect an Electronic Assembly Malfunction, turn the unit off, switch to your reserve oxygen system, and contact your DeVilbiss provider immediately.
  • R
    Robert JohnsonAug 26, 2025
    What to do if DeVilbiss Medical Equipment makes audible low-frequency vibration sound?
    • C
      Christina TorresAug 27, 2025
      If you detect an audible low-frequency vibration sound from your DeVilbiss Medical Equipment, turn the unit off, switch to your reserve oxygen system, and contact your DeVilbiss provider immediately, as this may indicate an Electronic Assembly Malfunction.
  • K
    Karen PhillipsAug 30, 2025
    What to do if any other problems occur with DeVilbiss oxygen concentrator?
    • G
      Gregory WhiteAug 30, 2025
      Turn your unit “Off.” Switch to your reserve oxygen system and contact your DeVilbiss provider immediately.

Summary

Important Safeguards

Danger Safety Information

Details immediate hazards that could result in death or serious injury.

Warning Safety Information

Details potential hazards that could result in death or serious injury.

Caution Safety Advice

Details potential hazards that could result in property damage or device damage.

Setting Up Your Oxygen Concentrator

Unit Positioning

Provides guidance on where and how to place the oxygen concentrator.

Oxygen Accessory Connection

Details how to connect tubing, humidifiers, and other accessories.

Operating Your DeVilbiss Oxygen Concentrator

Powering On the Unit

Steps for turning the oxygen concentrator on and initial startup indicators.

Flow Meter Adjustment

Guidance on setting the flow rate using the flow meter knob.

Troubleshooting

Minor Troubleshooting Chart

Provides solutions for common unit malfunctions and error symptoms.

Overview of Alarms

Alarm Conditions and Actions

Details the types of alarms, their indicators, and required actions.

Specifications

Electromagnetic Compatibility Information

MR Unsafe Warnings

Details warnings regarding MR environments and electronic interference.

DeVilbiss 525DS-Q Specifications

General IconGeneral
BrandDeVilbiss
Model525DS-Q
CategoryHealth Care Products
LanguageEnglish

Related product manuals