EN
Check distance (normally 150-
200mm).
Runs and sags.
Ball end heavy
pattern.
Gun too far from surface.
Too much air pressure.
Excessive bounce-back.
Too much fluid flow.
Change fluid tip for smaller size or
change air cap for different
specification air cap.
Too much atomisation air pressure.
Reduce air pressure and check spray
pattern.
Adjust gun or reduce fluid pressure.
Reduce air pressure.
Increase fluid flow by changing fluid
tip size, supply pressure or turning
needle control knob counter
clockwise.
Too much fluid flow.
Gun too far from surface.
Thin, sandy coarse finish drying
before it flows out.
Mount gun at right angle to work.
Material too thin.
Mix properly or apply light
coats/reduce fluid flow.
Gun tilted at an angle.
Check distance.
Fluid flow too low.
SB-E-2-643 R5.0
22/28