EasyManua.ls Logo

DeVilbiss FA125 - User Manual

DeVilbiss FA125
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MODEL NO.
FA125
FAC125
MGP-FA125-2A 9/18/99
SAFETY GUIDELINES - DEFINITIONS
Information for preventing damage to
equipment.
This manual contains information
that is important for you to know
and understand. This information
relates to protecting YOUR
SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To
help you recognize this informa-
tion, we use the symbols to the
right. Please read the manual and
pay attention to these sections.
URGENT SAFETY INFORMATION - A HAZARD
THAT WILL CAUSE SERIOUS INJURY OR LOSS
OF LIFE.
Information that you should pay
special attention to.
IMPORTANT SAFETY INFORMATION - A
HAZARD THAT MIGHT CAUSE SERIOUS
INJURY OR LOSS OF LIFE.
Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service
Center for ordering repair parts and for warranty repairs.
When ordering repair parts from your local Authorized Service Center, always give the following information:
Model number of your compressor
Part number and description of the item you wish to purchase
OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
SAFETY GUIDELINES .......................................................... 1
WARRANTY ........................................................................ 2
WARNING CHART ........................................................... 3-4
GLOSSARY ......................................................................... 5
DUTY CYCLE ....................................................................... 5
STORAGE ............................................................................ 5
DESCRIPTION OF OPERATION ........................................... 6
INSTALLATION AND BREAK-IN
PROCEDURES ................................................................ 6-7
Location of Air Compressor ........................................ 6
Extension Cords .......................................................... 6
Voltage and Circuit Protection .................................... 6
Grounding Instructions ................................................ 7
Additional Regulators and Controls ............................ 7
Break-In Procedures ................................................... 7
OPERATING PROCEDURES ................................................ 8
TROUBLESHOOTING GUIDE ......................................... 9-10
COMPRESSOR PARTS LIST ............................................ 11
TABLE OF CONTENTS
MODEL NO.
Horsepower
SCFM @ 40 psig
SCFM @ 90 psig
Cut-In
Cut-Out
Bore
Stroke
Voltage/Hertz/ Phase
Minimum Branch Circuit
Requirement
*Fuse Type
Amperage at Max. Load
Tank Size
SPECIFICATION CHART
*A circuit breaker is preferred. Use only a fuse or
circuit breaker that is the same rating as the branch
circuit the air compressor is operated on. If the air
compressor is connected to a circuit protected by
fuses, use quick acting fuses.
FA125
1
3.7
2.7
100 PSI
125 PSI
1 3/4"
1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
FAC125
-----
3.7
2.7
100 PSI
125 PSI
1 3/4"
1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon

Questions and Answers

  • M
    Miranda MedinaJul 29, 2025
    Why does the DeVilbiss Air Compressor tank pressure get too high?
    • J
      Jacob JohnsonJul 29, 2025
      Excessive tank pressure in your DeVilbiss Air Compressor, causing the safety valve to pop off, is often due to the pressure switch failing to shut off the motor when the compressor reaches its cut-out pressure, or the pressure 'cut-out' is set too high. To resolve this, move the pressure switch lever to the 'OFF' position. If it still doesn’t shut off, unplug the unit. If the electrical contacts are welded together, the pressure switch needs replacement. You may need to return the air compressor to an authorized dealer to check, adjust, or replace the switch.
  • J
    Jeremy HollandAug 3, 2025
    What to do if my DeVilbiss FA125 has air leaks at fittings?
    • B
      Beth JamesAug 3, 2025
      If you notice air leaks at the fittings of your DeVilbiss Air Compressor, it's likely because the tube fittings aren't tight enough. Try tightening the fittings where you hear air escaping. You can also check the fittings with a soapy water solution to identify leaks. Be careful not to overtighten.
  • L
    lindsaypenaAug 8, 2025
    What to do if my DeVilbiss Air Compressor air tank is leaking?
    • P
      Penny JohnsonAug 9, 2025
      If your DeVilbiss Air Compressor has air leaks in the air tank or at the air tank welds, it indicates a defective air tank. The air tank must be replaced. Do not attempt to repair the leak, and do not drill into, weld, or otherwise modify the air tank, as this will weaken it and could cause it to rupture or explode.
  • A
    Ashley HarrisAug 13, 2025
    What to do if my DeVilbiss FA125 has air leaks at pressure switch release valve?
    • J
      Justin DiazAug 13, 2025
      If your DeVilbiss Air Compressor has air leaks at the pressure switch release valve, it could be due to a defective pressure release valve or a defective check valve. Try removing and replacing the release valve. Also, a defective check valve can cause a constant air leak at the pressure release valve when there's pressure in the tank and the compressor is shut off. In this case, remove and clean or replace the check valve. Be careful not to overtighten.
  • H
    Henry HillAug 18, 2025
    How to fix air leaks inside the check valve of DeVilbiss FA125?
    • A
      April ScottAug 18, 2025
      If you have air leaks at or inside the check valve of your DeVilbiss Air Compressor, the check valve may be defective or dirty. Remove and clean or replace the check valve. Be careful not to overtighten.
  • V
    vargasangelaAug 23, 2025
    Why does the pressure drop on my DeVilbiss Air Compressor when using an accessory?
    • D
      Dalton GilbertAug 23, 2025
      It is normal for some pressure drop to occur on your DeVilbiss Air Compressor when an accessory is used. However, if there is an excessive amount of pressure drop, adjust the regulator following the instructions. Make sure to adjust the regulated pressure under flow conditions, meaning while the accessory is being used.

Summary

Safety Guidelines Definitions

Limited Warranty

Important Safety Instructions

Risk of Bursting

Explains conditions leading to tank explosion, emphasizing proper draining and no modifications.

Risk of Explosion or Fire

Warns about flammable vapors and the need for ventilation and proper placement.

Risk of Electrical Shock

Highlights dangers of electricity and the need for proper grounding and avoiding wet conditions.

Risk from Flying Objects

Covers hazards from compressed air stream, recommending safety glasses and proper aiming.

Installation and Break-in Procedures

Operating Procedures

Troubleshooting Guide

DeVilbiss FA125 Specifications

General IconGeneral
ModelFA125
Tank Capacity4.5 Gallons
Tank Size4.5 Gallons
Max Pressure125 PSI
Pump TypeOil-Free
Power SourceElectric
Voltage120V
Horsepower1.5 HP