50
ENGLISH
TROUBLESHOOTING
Problem Solution
Unit will notstart. Check batteryinstallation.
Check battery
chargingrequirements.
Check that lock off is fully pushed
down prior to moving maintrigger.
Unit shuts down
inuse.
Chargebattery.
Unit is being forced. Restart and
apply lesspressure.
Battery
won’tcharge.
Insert battery into charger until red
charging light illuminates. Charge up
to 8 hours if battery is totallydrained.
Plug charger into a working outlet.
Refer to Important Charging Notes
for moredetails.
Check current at receptacle by
plugging anappliance.
Check to see if receptacle is
connected to a light switch which
turns power off when you turn out
thelights.
Move charger and appliance to
a surrounding air temperature of
above 4.5°C or below 40.5°C.
Bar /
Chainoverheated.
Refer to
Adjusting Chain
Tension
section.
Refer to
Chain Oiling
section.
Chain isloose. Refer to Adjusting Chain
Tensionsection.
Poor cutquality.
Refer to
Adjusting Chain
Tension
section.
NOTE:
Excessive
tension leads to excessive wear and
reduction in life of bar and chain.
Lubricate before each cut. Refer to
Replacing the Saw Chain
section.
Unit runs but does
notcut.
Chain could be installed backwards.
Refer to sections for installing and
removingchain.
Unit does notoil. Refill oilreservoir.
Clean guide bar, sprocket and
sprocket cover. Refer to Care And
Maintenancesection.