4
ENGLISH
Connect the brown lead to the live terminal in theplug.
Connect the blue lead to the neutralterminal.
WARNING: No connection is to be made to the
earthterminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 13A.
Using an Extension Cable
An extension cord should not be used unless absolutely
necessary. Use an approved extension cable suitable for
the power input of your charger (see Technical Data). The
minimum conductor size is 1mm
2
; the maximum length
is30m.
When using a cable reel, always unwind the cablecompletely.
Grounding Instructions
The charger/radio must be grounded. In the event of
malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of electric
shock. The charger/radio is equipped with a cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
andordinances.
DANGER: Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. The conductor with insulation having an outer
surface that is green with yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal. Repairs shall only
be performed by a D
e
WALT service agent. Do not modify
the plug provided with the charger/radio – if it will not
fit the outlet, have a proper outlet installed by a D
e
WALT
repairagent.
For grounded, cord-connected charger/
radio rated 16A and lower and intended
for use on a nominal 230V supply circuit
The charger/radio is for use on a nominal 230 V circuit,
and has a grounding plug that looks like the plug in the
followingillustration.
DCR027-BD, -QW DCR027-GB DCR027-XE
SAVE THESE INSTRUCTIONS
Chargers
DeWALT
chargers require no adjustment and are designed to be
as easy as possible tooperate.
Important Safety Instructions for Charger/
Radios
SAVE THESE INSTRUCTIONS: This manual contains important
safety and operating instruc tions for the your charger/radio.
Before using charger/radio, read all instructions and
cautionary markings on charger, battery pack, and product
using batterypack.
WARNING: Shock hazard. Do not allow any liquid to get
inside charger. Electric shock mayresult.
WARNING: We recommend the use of a residual current
device with a residual current rating of 30mA orless.
CAUTION: Burn hazard. To reduce the risk of injury,
charge only
DeWALT
rechargeable batteries. Other types of
batteries may burst causing personal injury anddamage.
CAUTION: Children should be supervised to ensure that
they do not play with theappliance.
NOTICE: Under certain conditions, with the charger
plugged into the power supply, the exposed charging
contacts inside the charger can be shorted by foreign
Batteries
Chargers/Charge Times (Minutes)
Cat #
DC
Weight
Batteries Chargers/Charge Times (Minutes)
Cat # V
DC
Ah
Weight
kg
DCB107 DCB113 DCB115 DCB118 DCB132 DCB119
DCB546 18/54 6.0/2.0 1.05 270 140 90 60 90 X
DCB547 18/54 9.0/3.0 1.25 420 220 140 85 140 X
DCB181 18 1.5 0.35 70 35 22 22 22 45
DCB182 18 4.0 0.61 185 100 60 60 60 120
DCB183/B 18 2.0 0.40 90 50 30 30 30 60
DCB184/B 18 5.0 0.62 240 120 75 75 75 150
DCB185 18 1.3 0.35 60 30 22 22 22 X
DCB187 18 3.0 0.48 140 70 45 45 45 90