2
ENGLISH
GENERAL POWER TOOL SAFETY WARNINGS
WARNING: Read all safety warnings, instructions, illustrations and specifications
provided with this power tool. Failure to follow all instructions listed below may result in
electric shock, fire and/or seriousinjury.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR
FUTURE REFERENCE.
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-
operated (cordless) powertool.
Work Area Safety
a ) Keep work area clean and well lit. Cluttered or dark areas inviteaccidents.
b ) Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust
orfumes.
c ) Keep children and bystanders away while operating a power tool. Distractions can
cause you to losecontrol.
Electrical Safety
d ) Power tool plugs must match the outlet. Never modify the plug in any way. Do not
use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and
matching outlets will reduce risk of electricshock.
e ) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is earthed
orgrounded.
f ) Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electricshock.
g ) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electricshock.
h ) When operating a power tool outdoors, use an extension cord suitable for outdoor
use. Use of a cord suitable for outdoor use reduces the risk of electricshock.
i ) If operating a power tool in a damp location is unavoidable, use a ground
fault circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of
electricshock.
Personal Safety
j ) Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the influence of
drugs, alcohol or medication. A moment of inattention while operating power tools may
result in serious personalinjury.
k ) Use personal protective equipment. Always wear eye protection. Protective
equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for
appropriate conditions will reduce personalinjuries.
l ) Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or energizing power tools that have the
switch on invitesaccidents.
m ) Remove any adjusting key or wrench before turning the power tool on. A wrench or a
key left attached to a rotating part of the power tool may result in personalinjury.
n ) Do not overreach. Keep proper footing and balance at all times. This enables better
control of the power tool in unexpectedsituations.
o ) Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing and
gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in
movingparts.
p ) If devices are provided for the connection of dust extraction and collection facilities,
ensure these are connected and properly used. Use of dust collection can reduce dust-
relatedhazards.
q ) Do not let familiarity gained from frequent use of tools allow you to become
complacent and ignore tool safety principles. A careless action can cause severe injury
within a fraction of asecond.
Power Tool Use and Care
r ) Do not force the power tool. Use the correct power tool for your application. The
correct power tool will do the job better and safer at the rate for which it wasdesigned.
Technical Data
DHS790
Voltage
V
DC
2 x 54 (60V Max)
Battery Type
Li-Ion
Blade diameter
mm 305
Blade bore
mm 25.4
Blade body thickness
mm 1.75
Max. blade speed
min
-1
3 800
Max. cross-cut capacity 90°
mm 345
Max. mitre capacity 45°
mm 244
Max. depth of cut 90°
mm 112
Max. depth of bevel cross-cut 45°
mm 56
Mitre (max. positions)
left 50°
right 60°
Bevel (max. positions)
left 49°
right 49°
Automatic blade brake time
s < 5
Weight (without battery packs or corded power supply)
kg 25.3
Batteries Chargers/Charge Times (Minutes)
Cat # V
DC
Ah Weight (kg) DCB107 DCB112 DCB115 DCB118 DCB132 DCB119
DCB546 18/54 6.0/2.0 1.05 270 140 90 60 90 X
DCB606 20/60 6.0/2.0 1.05 270 140 90 60 90 X
DCB547 18/54 9.0/3.0 1.25 420 220 140 85 140 X
DCB609 20/60 9.0/3.0 1.25 420 220 140 85 140 X
DCB181 18 1.5 0.35 70 35 22 22 22 45
DCB182 18 4.0 0.61 185 100 60 60 60 120
DCB204 20 4.0 0.61 185 100 60 60 60 120
DCB183/B 18 2.0 0.40 90 50 30 30 30 60
DCB203 20 2.0 0.40 90 50 30 30 30 60
DCB184/B 18 5.0 0.62 240 120 75 75 75 150
DCB205 20 5.0 0.62 240 120 75 75 75 150
DCB185 18 1.3 0.35 60 30 22 22 22 X
DCB187 18 3.0 0.48 140 70 45 45 45 90