Before using an extension cord, inspect it for loose or exposed wires,
damaged insulation, and defective fittings. Make any needed repairs or
replace the cord if necessary.
Full Warranty
DEWALT heavy duty industrial tools are warranted for one year from
date of purchase. We will repair, without charge, any defects due to
faulty materials or workmanship. Arrangements have been made
with the Industrial Tool Division of Black & Decker (U.S.) Inc. to
provide warranty repairs for D
EWALT tools. Please return the
complete unit, transportation prepaid, to any Black & Decker (U.S.)
Inc. Industrial Service Center or Authorized Service Station listed
under “Tools, Electric” in the Yellow Pages. This warranty does not
apply to accessories or damage caused where repairs have been
made or attempted by others. This warranty gives you specific
legal rights and you may have other rights which vary from state to
state.
In addition to the warranty, D
EWALT tools are covered by our:
30 DAY NO RISK SATISFACTION GUARANTEE
If you are not completely satisfied with the performance of your
D
EWALT heavy duty industrial tool, simply return it to the
participating seller within 30 days for a full refund. Please return the
complete unit, transportation prepaid. Proof of purchase may be
required.
15
Motor Brushes
DeWalt uses an advanced brush system which automatically stops
the drill when the brushes wear out. This prevents serious damage
to the motor.
Extension Cords
Double insulated tools have 2-wire cords and can be used with 2-
wire or 3-wire extension cords. Only round jacketed extension cords
should be used, and we recommend that they be listed by
Underwriters Laboratories (U.L.) (C.S.A. in Canada). If the
extension will be used outside, the cord must be suitable for outdoor
use. Any cord marked as outdoor can be used for indoor work. The
letters “WA” on the cord jacket indicate that the cord is suitable for
outdoor use.
An extension cord must have adequate wire size (AWG or
American Wire Gauge) for safety, and to prevent loss of power and
overheating. The smaller the gauge number of the wire, the greater
the capacity of the cable, that is 16 gauge has more capacity than
18 gauge. When using more than one extension to make up the
total length, be sure each individual extension contains at least the
minimum wire size.
To determine the minimum wire size required, refer to the chart
below.
CHART FOR MINIMUM WIRE SIZE (AWG)
OF EXTENSION CORDS
NAMEPLATE TOTAL EXTENSION CORD LENGTH-FEET
RATING-AMPS 25 50 75 100 125 150 175 200
0 - 10.0 18 18 16 16 14 14 12 12
10.1 - 13.0 16 16 14 14 14 12 12 12
13.1 - 15.0 14 14 12 12 12 12 12 —
See ‘Tools-Electric’
– Yellow Pages –