INSTRUCTION MANUAL
GUIDE DE’UTILISATION
MANUAL DE INSTRUCCIONES
Kerosene Forced-Air Heater DXH135HD, DXH190HD, DXH215HD
Kérosène air forcé Chauffage DXH135HD, DXH190HD, DXH215HD
El queroseno calentador de aire forzado DXH135HD, DXH190HD, DXH215HD
2017 - 40798 - CB
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, adjust or operate the heater.
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez ces
instructions dans un endroit sécuritaire pour vous y référer
ultérieurement. Interdisez à quiconque n’ayant pas lu les
présentes directives d’assembler, de régler ou de faire
fonctionner cette fournaise.
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
Lea y siga todas las instrucciones. Conserve
estas instrucciones en un lugar seguro para futura
referencia. No permita que nadie que no haya leído
estas instrucciones arme, ajuste o use el calentador.

Questions and Answers

  • M
    mayerdanaAug 17, 2025
    How to troubleshoot a flame control failure in a DeWalt DXH215HD?
    • N
      Nicholas BrownAug 17, 2025
      To address a flame control failure in your DeWalt Heater: * Check the wiring within the heater, referring to the wiring schematic in the manual. * Replace the oil flame control assembly.
  • P
    perezbrittanyAug 19, 2025
    What to do if my DeWalt Heater is unable to detect flame?
    • Z
      zunigacurtisAug 20, 2025
      If your DeWalt Heater can't detect a flame, try these steps: * Inspect the wiring to the cad cell using the wiring schematic in the manual. * Clean the cad cell photo cell. * If the heater still doesn't work, replace the cad cell.
  • G
    Gregory SmithAug 26, 2025
    How to troubleshoot a DeWalt Heater that has no spark?
    • D
      Denise HawkinsAug 26, 2025
      If your DeWalt Heater has no spark, consider the following: * Check the extension cord's length and gauge to ensure it meets the amp requirements (refer to page 5). * Inspect the wiring to the igniter using the wiring schematic in the manual. * Verify the gap between the electrode probes is between 2.3 and 3 mm. * If there's still no spark, replace the igniter assembly.
  • L
    Lucas OwensAug 28, 2025
    Why does my DeWalt Heater motor overheat or stop?
    • D
      Destiny BrooksAug 28, 2025
      If your DeWalt Heater's motor overheats or stops, here are some things to check: * The motor speed may be too low (it should operate at 3450rpm, except for the 50K model at 1550rpms). If so, replace the motor. * With the heater disconnected from the AC source, rotate the fan clockwise to verify the motor is free. * Remove the air filter housing from the motor and inspect the pump rotor for damage; replace the rotor assembly if damaged. * If the wiring is correct, the pump rotor is okay, and the motor is not rotating freely, replace the motor or power-pack assembly.
  • A
    ashleycrawfordAug 30, 2025
    What to do if my DeWalt DXH215HD cannot detect the flame?
    • A
      April BakerAug 31, 2025
      If your DeWalt Heater is unable to detect a flame: * Check the wiring to the cad cell using the wiring schematic in the manual. * Clean the cad cell photo cell by sliding it out of the holder, pushing the photo cell out of the rubber housing, cleaning it with a soft cloth and rubbing alcohol, and reinstalling it. * If the heater still doesn't operate, replace the cad cell.
  • G
    grantangelaSep 3, 2025
    How to fix a high limit switch open circuit on a DeWalt DXH215HD Heater?
    • D
      dominic88Sep 3, 2025
      If your DeWalt Heater's high limit switch has an open circuit, ensure the heater is cooled off, toggle the switch to the “O” position, wait 5 minutes, and then try again.
  • T
    timothyrodriguezSep 8, 2025
    How to fix a DeWalt DXH215HD when there is no spark?
    • M
      Michael HowellSep 8, 2025
      If your DeWalt Heater isn't sparking, consider the following: * Verify the extension cord's length and gauge are appropriate for the amp draw. Check the requirements on page 5 of the manual. * Inspect the wiring to the igniter using the wiring schematic in the manual. * Confirm the gap between the electrode probes is within the range of 2.3 to 3 mm. * If there's still no spark, replace the igniter assembly.
  • C
    Courtney HigginsSep 12, 2025
    Why does the motor in my DeWalt DXH215HD Heater overheat or stop?
    • S
      smithvanessaSep 12, 2025
      If the motor in your DeWalt Heater is overheating or stopping, it could be due to the following reasons: * The motor speed is too low, in which case you should replace the motor. * The motor may not be rotating freely. Disconnect the heater from the AC source and rotate the fan clockwise to check. * There might be damage to the pump rotor. Remove the air filter housing and inspect the pump rotor; replace if necessary. * If the wiring is correct, the pump rotor is okay, and the motor is still not rotating freely, replace the motor or power-pack assembly.
  • W
    William GutierrezSep 13, 2025
    How to reset the high limit switch on a DeWalt DXH215HD Heater?
    • J
      Joanne LewisSep 13, 2025
      To reset the high limit switch on your DeWalt Heater, ensure the heater has cooled down. Then, toggle the switch to the “O” position, wait 5 minutes, and try again.
  • K
    Kristen PerryNov 22, 2025
    What to do if my DeWalt DXH215HD has sparks but the motor isn't working properly?
    • W
      webbjonathanNov 22, 2025
      If your DeWalt Heater sparks and calls for a flame but the motor operates slowly or not at all: * First, check the wiring to the motor using the wiring schematic in the manual. * Ensure the pressure gauge plug is correctly in place and undamaged. * Adjust the pressure for proper heater operation as described in the manual. * With the heater disconnected, rotate the fan clockwise to ensure the motor is free. * Inspect the pump rotor for damage by removing the air filter housing from the motor. Replace the rotor assembly if damaged. * If the wiring is correct, the pump rotor is okay, and the motor doesn't rotate freely, replace the motor or power-pack assembly. * If the problem continues, replace the oil flame control assembly. * Also, check for spark arching from the electr...

Summary

Safety Guidelines

Hazard Severity Definitions

Defines DANGER, WARNING, CAUTION, and NOTICE levels for safety information.

Critical Safety Warnings

Covers essential safety warnings including carbon monoxide, fire, explosion, electrical shock, and California Prop 65.

Heater Specifications

Model Specifications

Provides detailed technical specifications for DXH135HD, DXH190HD, and DXH215HD models.

Operating Precautions

Ventilation and CO Risks

Details carbon monoxide hazards and the importance of adequate ventilation.

General Usage Safety

Covers safe practices regarding fuel, heater condition, placement, clearances, and electrical connections.

Assembly and Operation

Heater Assembly and Preparation

Guides on unpacking, assembling the heater, fueling, and initial setup.

Startup, Shutdown, and Restart

Instructions for starting, stopping, and restarting the heater after safety shutdowns.

Maintenance and Adjustment

Pump Pressure Adjustment

Procedure for adjusting pump pressure for optimal flame performance.

Maintenance Schedules

Details daily, 500-hour, and annual maintenance tasks for the heater.

Troubleshooting and Parts

Diagnostic Safety Shutdowns

Troubleshooting guide for common symptoms and safety shutdown issues.

Parts List

Comprehensive list of replacement parts for different heater models.

Warranty and Service

Parts Ordering Information

Information on how and where to order replacement parts.

Limited Warranty

Details the warranty period and terms for the kerosene heater.

DeWalt DXH215HD Specifications

General IconGeneral
Power SourcePropane
Heater TypeForced Air
Fuel TypePropane
BTU Output215, 000 BTU
Heating AreaUp to 5, 000 sq. ft.
Run TimeUp to 11 hours
Weight35 lbs
Dimensions15.75 x 22.5 x 17.5 inches
Ignition TypeElectronic
Voltage120V
Regulator IncludedYes
IgnitionElectronic