INSTRUCTION MANUAL
GUIDE DE’UTILISATION
MANUAL DE INSTRUCCIONES
Kerosene Forced-Air Heater DXH135HD, DXH190HD, DXH215HD
Kérosène air forcé Chauffage DXH135HD, DXH190HD, DXH215HD
El queroseno calentador de aire forzado DXH135HD, DXH190HD, DXH215HD
2017 - 40798 - CB
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, adjust or operate the heater.
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez ces
instructions dans un endroit sécuritaire pour vous y référer
ultérieurement. Interdisez à quiconque n’ayant pas lu les
présentes directives d’assembler, de régler ou de faire
fonctionner cette fournaise.
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
Lea y siga todas las instrucciones. Conserve
estas instrucciones en un lugar seguro para futura
referencia. No permita que nadie que no haya leído
estas instrucciones arme, ajuste o use el calentador.

Questions and Answers

  • R
    Ronnie MccoyAug 17, 2025
    How to troubleshoot a flame control failure in a DeWalt Heater?
    • K
      Kevin GarciaAug 17, 2025
      To address a flame control failure in your DeWalt Heater: * Check the wiring within the heater, referring to the wiring schematic in the manual. * Replace the oil flame control assembly.
  • P
    Patricia HarrisAug 20, 2025
    What to do if my DeWalt DXH190HD Heater is unable to detect flame?
    • M
      Mr. Grant FloresAug 20, 2025
      If your DeWalt Heater can't detect a flame, try these steps: * Inspect the wiring to the cad cell using the wiring schematic in the manual. * Clean the cad cell photo cell. * If the heater still doesn't work, replace the cad cell.
  • D
    Dominique GarciaAug 26, 2025
    How to troubleshoot a DeWalt DXH190HD Heater that has no spark?
    • K
      kimberly82Aug 26, 2025
      If your DeWalt Heater has no spark, consider the following: * Check the extension cord's length and gauge to ensure it meets the amp requirements (refer to page 5). * Inspect the wiring to the igniter using the wiring schematic in the manual. * Verify the gap between the electrode probes is between 2.3 and 3 mm. * If there's still no spark, replace the igniter assembly.
  • R
    Rachel GatesAug 28, 2025
    Why does my DeWalt DXH190HD Heater motor overheat or stop?
    • T
      Taylor WadeAug 28, 2025
      If your DeWalt Heater's motor overheats or stops, here are some things to check: * The motor speed may be too low (it should operate at 3450rpm, except for the 50K model at 1550rpms). If so, replace the motor. * With the heater disconnected from the AC source, rotate the fan clockwise to verify the motor is free. * Remove the air filter housing from the motor and inspect the pump rotor for damage; replace the rotor assembly if damaged. * If the wiring is correct, the pump rotor is okay, and the motor is not rotating freely, replace the motor or power-pack assembly.
  • M
    Matthew PerezAug 30, 2025
    What to do if my DeWalt DXH190HD Heater cannot detect the flame?
    • S
      Sharon IngramAug 31, 2025
      If your DeWalt Heater is unable to detect a flame: * Check the wiring to the cad cell using the wiring schematic in the manual. * Clean the cad cell photo cell by sliding it out of the holder, pushing the photo cell out of the rubber housing, cleaning it with a soft cloth and rubbing alcohol, and reinstalling it. * If the heater still doesn't operate, replace the cad cell.
  • B
    Brittany DavenportSep 2, 2025
    How to fix a high limit switch open circuit on a DeWalt DXH190HD Heater?
    • A
      Adrian WattsSep 2, 2025
      If your DeWalt Heater's high limit switch has an open circuit, ensure the heater is cooled off, toggle the switch to the “O” position, wait 5 minutes, and then try again.
  • G
    Gina HolderSep 8, 2025
    How to fix a DeWalt DXH190HD Heater when there is no spark?
    • A
      andrew21Sep 8, 2025
      If your DeWalt Heater isn't sparking, consider the following: * Verify the extension cord's length and gauge are appropriate for the amp draw. Check the requirements on page 5 of the manual. * Inspect the wiring to the igniter using the wiring schematic in the manual. * Confirm the gap between the electrode probes is within the range of 2.3 to 3 mm. * If there's still no spark, replace the igniter assembly.
  • L
    Lee MilesSep 12, 2025
    Why does the motor in my DeWalt DXH190HD Heater overheat or stop?
    • C
      Courtney DiazSep 12, 2025
      If the motor in your DeWalt Heater is overheating or stopping, it could be due to the following reasons: * The motor speed is too low, in which case you should replace the motor. * The motor may not be rotating freely. Disconnect the heater from the AC source and rotate the fan clockwise to check. * There might be damage to the pump rotor. Remove the air filter housing and inspect the pump rotor; replace if necessary. * If the wiring is correct, the pump rotor is okay, and the motor is still not rotating freely, replace the motor or power-pack assembly.
  • B
    brownstephanieSep 13, 2025
    How to reset the high limit switch on a DeWalt Heater?
    • J
      Joshua WebsterSep 13, 2025
      To reset the high limit switch on your DeWalt Heater, ensure the heater has cooled down. Then, toggle the switch to the “O” position, wait 5 minutes, and try again.
  • M
    Melissa GonzalezNov 21, 2025
    What to do if my DeWalt Heater has sparks but the motor isn't working properly?
    • D
      dgarciaNov 21, 2025
      If your DeWalt Heater sparks and calls for a flame but the motor operates slowly or not at all: * First, check the wiring to the motor using the wiring schematic in the manual. * Ensure the pressure gauge plug is correctly in place and undamaged. * Adjust the pressure for proper heater operation as described in the manual. * With the heater disconnected, rotate the fan clockwise to ensure the motor is free. * Inspect the pump rotor for damage by removing the air filter housing from the motor. Replace the rotor assembly if damaged. * If the wiring is correct, the pump rotor is okay, and the motor doesn't rotate freely, replace the motor or power-pack assembly. * If the problem continues, replace the oil flame control assembly. * Also, check for spark arching from the electr...

Summary

Safety Guidelines and Definitions

General Safety Warnings

Crucial safety warnings covering operation, CO, fire, and electrical hazards.

Risk of Fire or Explosion

Specific precautions to prevent fire and explosion hazards during operation.

Heater Specifications

Fire and Explosion Warning

Critical safety warning about fire and explosion risks with gas.

Gas Leak Emergency Procedure

Steps to take if you suspect a gas leak, emphasizing safety.

Operating Precautions

Heater Operating Precautions

Guidelines for safe and efficient operation of the kerosene heater.

General Safety Precautions

Essential safety measures covering fuel, damage, modification, and location.

Operating Instructions: Unpacking

Heater Operation

Pump Pressure Adjustment

Maintenance Schedules

Annual Maintenance and Servicing

Servicing Safety Warning

Crucial safety warning regarding heater modification and proper service.

Wiring Diagram

Troubleshooting

No Spark Troubleshooting

Steps to take if the heater is not producing a spark.

Unable to Detect Flame

How to diagnose and fix issues where the flame is not detected.

DeWalt DXH190HD Specifications

General IconGeneral
Heating Capacity190, 000 BTU
Weight80 lbs
Dimensions47.5 x 21.5 x 24.5 inches
Heater TypeForced Air
Fuel TypeKerosene / Diesel / Fuel Oil
Electrical120V, 60Hz
Heating Area4750 sq ft
IgnitionElectronic
Tank ConnectionStandard propane tank connection

Related product manuals