EasyManua.ls Logo

DeWalt DXH190HD - Heater Specifications; Fire and Explosion Warning; Gas Leak Emergency Procedure

DeWalt DXH190HD
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
Specifications
CAUTION: CSA certified for use with only No. 1-K kerosene fuel. Factory Tested:
No.2-K kerosene, No.1 or No.2 Diesel, No.1 or No.2 fuel oil or JP8 Jet A fuel
CONTENTS
WARNINGS ......................................................................... 2-3
HEATER SPECIFICATIONS ..................................................... 3
OPERATING PRECAUTIONS .................................................. 4
SAFETY PRECAUTIONS......................................................... 4
OPERATING INSTRUCTIONS .............................................. 4-5
MAINTENANCE, STORAGE AND SERVICE ........................ 5-7
WIRING DIAGRAM ................................................................. 7
TROUBLE SHOOTING............................................................ 8
PARTS LISTS/EXPLODED VIEWS...................................... 9-11
WARRANTY ......................................................................... 12
INSTRUCTIONS FOR ORDERING PARTS ............................ 12
WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS?
• Open windows.
DO NOT try to light any appliance.
DO NOT operate any electrical switches.
DO NOT use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier’s instructions.
DO NOT touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
MODEL : DXH135HD DXH190HD DXH215HD
BURN RATE: 35,000 Btu/hr (39.5 kw) 190,000 Btu/hr (55.6 kw) 215,000 Btu/hr (62.9 kw)
FUEL RATE: 1.0 gal /HR (3.8 L / HR) 1.4 gal/hr (5.3 L /HR) 1.61 gal/hr (6.1 L /HR)
ELECTRICAL INPUT: 115V, 60Hz, 5.5A 115V, 60Hz, 5.5A 115V, 60Hz, 5.5A
LINE PROTECTION: 20 AMPS 20 AMPS 20 AMPS
MIN. OPERATING VOLTAGE: 110V 110V 110V
PRESSURE SETTING: 6.8 PSI (47 kPA) 7.5 PSI (51.7 kPA) 8.4 PSI ( 57.9 kPA)
MAX. OUTLET TEMPERATURE: 1450 °F (787°C) 1450 °F (787°C) 1450 °F (787°C)
FUEL TANK CAPACITY 14 gal (53 L) 14 gal (53 L) 14 gal (53 L)
IGNITION: Direct Spark, Continuous Direct Spark, Continuous Direct Spark, Continuous
SPARK GENERATOR: Igniter, 13 kV, 10mA Igniter, 13 kV, 10mA Igniter, 13 kV, 10mA
PRIMARY SAFETY CONTROL: Solid State Control Solid State Control Solid State Control
CERTIFICATION: CSA CSA CSA
UC U C UC