R

ł
󾙓󾙒󾙒󾙓󾙕󾙔
󾙚󾙒󾙓󾙕󾙔
󾙘󾙒󾙓󾙕󾙔
󾙗󾙒󾙓󾙕󾙔
󾙓󾙔󾙒󾙓󾙕󾙔
󾙓󾙗󾙒󾙓󾙕󾙔
󾙔󾙒󾙒󾙓󾙕󾙔
󾙔󾙗󾙒󾙓󾙕󾙔

Other manuals for Deye SUN-15K-SG01HP3-EU-AM2

Questions and Answers

  • M
    mmooreSep 12, 2025
    What does Tz_AC_OverCurr_Fault mean on my Deye SUN-15K-SG01HP3-EU-AM2 Inverter?
    • D
      Dr. Kristina Evans DVMSep 12, 2025
      If your Deye Inverter displays a Tz_AC_OverCurr_Fault due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • R
    roy38Aug 25, 2025
    What to do if my Deye SUN-15K-SG01HP3-EU-AM2 Inverter shows AC_Overload_Fault?
    • E
      edwardfitzgeraldAug 25, 2025
      If your Deye Inverter displays an AC_Overload_Fault, check the backup load connection to ensure it is within the allowed power range.
  • C
    Charles ElliottAug 25, 2025
    What does it mean if my Deye SUN-15K-SG01HP3-EU-AM2 Inverter shows DC_Insulation_Fault?
    • L
      lindsay47Aug 26, 2025
      If your Deye Inverter shows a DC_Insulation_Fault, it means the PV isolation resistance is too low. You should check if the connection of PV panels and the inverter is firm and correct. Also, verify whether the PE cable of the inverter is connected to ground.
  • B
    brian56Sep 23, 2025
    What does Tz_EmergStop_Fault mean on my Deye Inverter?
    • B
      Brian McdonaldSep 23, 2025
      If your Deye Inverter displays a Tz_EmergStop_Fault, it means the inverter is being remotely controlled.
  • L
    Lauren JohnsonSep 12, 2025
    What does AC_OverCurr_SW_Failure mean on my Deye SUN-15K-SG01HP3-EU-AM2 Inverter?
    • C
      Carrie TorresSep 12, 2025
      If your Deye Inverter displays an AC_OverCurr_SW_Failure due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • R
    ryan31Sep 16, 2025
    What does INVERTER_Manual_OFF mean on my Deye SUN-15K-SG01HP3-EU-AM2?
    • T
      Trevor FigueroaSep 16, 2025
      If your Deye Inverter displays INVERTER_Manual_OFF, check whether the switch of the inverter is turned on. You can also try restarting the inverter and restoring the factory settings.
  • T
    Timothy ShawSep 5, 2025
    What to do if Deye SUN-15K-SG01HP3-EU-AM2 shows Grid_phase_warn?
    • M
      Michele GeorgeSep 5, 2025
      If your Deye Inverter displays a Grid_phase_warn, check the phase sequence connection of the power grid. Try changing the grid type. If there is still no solution check the wiring at the grid end.
  • T
    Tony AllenSep 5, 2025
    What to do if Deye Inverter shows VW_activate?
    • W
      William YoungSep 5, 2025
      If your Deye Inverter displays VW_activate, measure whether the grid port voltage is too high and check whether the AC cable is too thin to carry current.
  • J
    Jennifer SnyderSep 17, 2025
    What does Parallel_Version_Fault mean on my Deye Inverter?
    • A
      Adam MasseySep 17, 2025
      If your Deye Inverter displays a Parallel_Version_Fault, check whether the inverter versions are consistent. You may need to contact support to upgrade the software version.
  • S
    Samantha GalvanAug 30, 2025
    What does it mean if my Deye Inverter shows DC_VoltHigh_Fault?
    • L
      Lauren WhiteAug 30, 2025
      If your Deye Inverter displays a DC_VoltHigh_Fault, it means the BUS voltage is too high. Check if the battery voltage is too high and verify that the PV input voltage is within the allowed range.

Deye SUN-15K-SG01HP3-EU-AM2 Specifications

General IconGeneral
ModelSUN-15K-SG01HP3-EU-AM2
TypeHybrid Inverter
Rated Power15000 W
Max. DC Input Voltage1000V
Starting Voltage200 V
MPPT Efficiency99.9%
Number of MPPTs2
Number of MPPT Trackers2
Max. Input Current per MPPT26 A
Nominal AC Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Protection DegreeIP65
Operating Temperature Range-25°C to +60°C
Cooling MethodSmart cooling
Protection ClassI
Max. DC Input Power19500W
Max. AC Output Power16500 VA
CommunicationRS485, Wi-Fi
AC Voltage Range180-280V