13
GENERAL MEASUREMENTS ON THE OUTSIDE OF ALL THE CABINETS AND EMERGENCY
DRAINAGE ANNOTATION IN MM
1.4 START-UP
Once the inside of the cabinet is clean, plug it into the electricity network and turn the switch
to On or I.
The thermostat temperature indicates the cabinet inner temperature.
Three minutes after turning the switch on, the compressor operating led must be
permanently on.
At the start, the temperature appearing on the temperature sight at the beginning will be
room temperature. With the machine operating, if the doors are shut, this temperature will
drop to the operating value.
The cabinet must be on until the working temperature is reached before filling it with
the goods.
Control panel with switch
and thermostat
2 USE
2.0 USE AND LOCATION RESTRICTIONS.
This machine must not be placed outdoors, and must be protected from rain and direct sunlight. Environmental
conditions: see characteristics plate.
This equipment is not designed to store explosive substances such as aerosol cans with flammable propellant.
WARNING: The appliance contains in the refrigerant circuit the refrigerant propane (R290) or isobutane
(R600a), a highly environmentally compatible natural gas that is inflammable. While transporting and installing
the appliance ensure that no parts of the refrigerant circuit are damaged.
Procedure if the refrigerant circuit is damaged:
- Avoid open fire and ignition sources at all costs
- Ensure that the room in which the appliance is located is well ventilated
The manufacturer is not responsible for any operation not mentioned in this manual, having to be followed the
next recommendations and warnings.
WARNING: Make sure all the ventilation grilles in the room where the appliance is to be located, or in the
structure housing it, are kept clear.