16
3.2 MACHINE CHECK
If you have to call for a repairperson, you can check the cabinet before ringing. In some cases,
the operating faults that can occur are caused by something simple that the users themselves
can solve.
The following are examples:
a) The refrigerator does not work
Check that electricity reaches the refrigerator by checking if the power switch is on.
b)
Temperature too low
Check that there are no heat sources nearby.
Check that the thermostat cut off point is very near to 0 ºC/-18 ºC. To do so, press the “set”
key once and stop pressing it.
Check that the room temperature is not above +43 ºC, the appliance's maximum operating
temperature.
Check that the goods load is perfectly positioned and does not obstruct the outlets of the
inner fan, and that the time it has been inside is sufficient to cool the products.
Check that the doors close properly.
c)
In the event of strange or excessive noise
Check the unit's levelling and that the doors close properly.
Check that there are no objects touching any of the refrigerator's moving components.
3.3 SPECIAL MAINTENANCE
(Authorised technical personnel)
Check that the premise's temperature does not exceed that indicated for your cabinet.
The guarantee will be made void if there is insufficient ventilation.
Check that the doors close properly.
Do not disassemble the mobile components guards without first having turned the appliance
off.
Take all the necessary precautions before accessing the area of the condenser unit, given the
existence of high temperatures of some components, with the resulting risk of burns.
If the flexible power cable or cord is damaged, it must be replaced by the manufacturer,
after-sales service or authorised technical personnel in order to prevent risks.
It if is replaced, the earth pin must be positioned again.
If you need to change a cable, you must never use a smaller section.
The electrical connections are carried out with 6.35 mm Faston terminals, protected with
covers.
If it is necessary to disassemble the inner lid of the control panel’s electrical installation, it is
extremely important to leave it exactly as it was when reassembling it.