Digi Connect and ConnectPort TS Family web interface Configuration through the web interface
Digi Connect Family and ConnectPort TS Family
62
n TCPSockets for TCP server: A TCP Server configuration allows other network devices
to initiate a TCP connection to the serial device attached to a serial port of the Digi
device server. This is also referred to as reverse telnet, console management or device
management.
a. Record the TCP (or SSH) port number listed under TCPServer Settings. You
will need the TCP port number when configuring an application or device
that accesses the serial port from the network.
b. Click Basic Serial Settings, complete the fields to match the settings of the
attached serial device or terminal, and then click Apply.
Note Configure the application or device that initiates communication to the serial port
from the network with the following information:
l IP address of this Digi device server.
l TCP or (SSH)port number for the serial port recorded above in Step a.
n UDP Sockets for UDP client (data distribution): UDP client configuration allows the
automatic distribution of serial data from one host to many devices at the same time
using UDP sockets. This is also referred to this as UDP Multicast.
a. Under UDPClient Settings, provide the following information for each UDP
destination:
l A description of the destination.
l The destination IP Address or DNS name.
l The destination UDP port.
When finished, click Add.
b. Select the options that define when to send data and click Apply.
c. Click Basic Serial Settings, complete the fields to match the settings of the
attached serial device or terminal, and then click Apply.
n UDPSockets for a UDP server:
a. Record the UDPport number listed under UDPServer Settings. You will
need the UDP port number when configuring an application or device that
accesses the serial port from the network.
b. Click Basic Serial Settings, complete the fields to match the settings of the
attached serial device, and then click Apply.
Note Configure the application or device that initiates communication to the serial port
from the network with the following information:
l IP address of this Digi device server.
l UDP port number for the serial port recorded previously in Step a.