7
4G Industrial VPN Quick Guide
2. INSTALLATION
2.1. FRONT VIEW
4G Industrial VPN
ETH0 ETH1
RUN PPP USR
RST
LED Indicators
NAME COLOR STATUS FUNCTION
1 RUN Green Blinking Routerisready
On Routerisstarting
Off Routerispoweroff
2 PPP Green Blinking PPPIndicator:Null
On PPPIndicator:PPPconnectionisup
Off PPPIndicator:PPPconnectionisdown
3 USR Green Blinking SIM:usingbackupSIMcard
NET:registertoalowlevelnetwork
Offafterblinking SIM:workingne
NET:workingne
Lightup OpenVPN:OpenVPNisconnected
IPSec:IPSecisconnected
GRE:GREisconnected
Offafterlightingup OpenVPN:OpenVPNisdisconnected
IPSec:IPSecisdisconnected
GRE:GREisdisconnected
Green On Signallevel:21-31(Perfectsignallevel)
Yellow On Signallevel:11-20(Averagesignallevel)
Red On Signallevel:1-10(Exceptionalsignallevel)
4
When the network is disconnected, those three signal LEDs are designed as a binary combination code to indicate
a series of error report.
(GreenYellowRed)On:1Off:0
001 AT command failed
010 no SIM card detected
011 requiresPINcode
100 requiresPUKcode
101 registration failed
110 something wrong happened in the module
Note: The user can select display status of USR LED. For details please refer to Service->Advanced section.
Reset Button
FUNCTION OPERATION
5 Reboot Pushthebuttonfor2~7secondsunderworkingstatus
Restore to factory default setting Pleasekeeppressingthe"RST"buttononcepowerontherouter,untilLED
lights blink one by one circularly
WhenthesixLEDlightsstartblinkingonebyone,pleasereleasethepressingoperationwithin5seconds.Inthistimethe
router loads default successfully.