Battery Replacement*
Support
It is not necessary to uninstall the lock from the door.
a.
Remove the screw and the battery cover.
b. Replace the four premium AA batteries.
c. Replace battery cover and screw.
Low Battery Indicator
After locking or unlocking, the lock emits two sets of three beeps indicating that the batteries are low. Replace the batteries.
Does not Unlock with the User RFID Credential or User Key
The lock does not recognize the User RFID Credential or User Key. For immediate access, operate with a valid Manager Credential. If in
assigned use functionality, follow instructions to Assign User Credentials to assign a new User RFID Credential or User Key to the lock.
Does not Operate with a Manager Credential
The lock does not recognize the Manager Credential. Follow instructions to Add Manager Credentials to program the Manager Credential to
the lock. For immediate access, operate with another valid Manager Credential.
Does not Operate with the Programming Key
The lock does not recognize the Programming Key. If the Programming Key has been replaced, operate with the Replacement Programming
Key. Contact Digilock support for additional assistance.
No Audible Feedback when ` is Touched
The batteries may need to be replaced. For immediate access, operate with a valid Manager Credential. If the error condition persists,
replace the batteries.