EDGEVIS HD-IP250 HARDWARE INSTALLATION
ISSUED: 10 NOVEMBER 2020 PAGE 2
Section 3 – Advanced fan configuration
HD-IP250 users may wish to deploy into environments where low noise is
desired. For these scenarios the fan can be disabled and the unit will run
silently, however an understanding of the operating limits of the HD-IP250
is essential.
Operating temperature limits with or without fan enabled
Below are the ambient operating temperature limits:
If the unit is used in an environment that exceeds the maximum stated temperature:
Damage may be caused to the unit.
Reduced encoding performance may be observed.
Enabling/disabling the fan
After logging into the local web interface navigate to the Power Settings page. The fan setting can be switched
between on and off. The setting will be applied immediately and will be used when the unit powers up.
Note - When the encoder is initially powered on, the fan will remain off until the unit has fully booted and taken
control of the fan.
FAN STATE
MIN Temperature
MAX Temperature
ON
-20°C / -4°F
60°C / 140°F
OFF
-20°C / -4°F
50°C / 122°F