The fare-cost is VAT included? - Should the fare-cost be considered inclusive VAT? If so, on the ticket the fare-cost will be split into cost and VAT.
If not, the fare-cost is considered Exclusive VAT. At the end of the fare the VAT will be added to the fare-cost.
The allowed answer is either: 0 (No: excl. VAT so add) or: 1 (Yes: incl. VAT so split).
Print ticket if from Stopped to ForHire? - Should the ticket be printed automatically if from Stopped is being passed to ForHire?
The allowed answer is either: 0 (No: don't print autom.) or: 1 (Yes: print autom.).
Print all income for each used tariff? - Should all income for each used tariff be printed on the ticket?
The allowed answer is either: 0 (No: don't print all income) or: 1 (Yes: print all income).
Print all kilometres made for each used tariff? - Should all kilometres made for each used tariff be printed on the ticket?
The allowed answer is either: 0 (No: don't print all kilometres made) or: 1 (Yes: print all kilometres made).
Print the maximum speed of the trip? - Should the maximum speed of the trip be printed on the ticket?
The allowed answer is either: 0 (No: don't print maximum speed) or: 1 (Yes: print maximum speed).
Hide the driver number on the ticket? - Should the driver number be hidden on the ticket? The allowed answer is either: 0 (No: don't hide) or: 1 (Yes: hide).
IR SENSOR FOR PASSENGER DETECTION
Distance to enable registration or ForHire: this is the distance that enables either the registration of the black fare with a passenger aboard in Stopped or the automatic
activation of Hired. See Q.313. The distance is given in metres with an accuracy of 0.1 meter. The allowed value goes from 0.0 (min) to 6553.5 (max). The digit indicating
multiples of 0.1 m (so at the right of the decimal point) will flash.
IR-sensor for passenger-det. is present? - Is the Infra-Red-sensor for the detection of passengers present?
The allowed answer is either: 0 (No: not present) or: 1 (Yes: present).
IR-sensor contact is normally closed? - Is the Infra-Red-sensor contact a Normally Closed contact ? If not, then it is a Normally Open contact.
The allowed answer is either: 0 (No: normally open) or: 1 (Yes: normally closed).
Black fare registr. or autom. in Hired? - After the distance programmed in Q.310 should be activated either: the registration in memory of the black fare with a
passenger aboard in Stopped or the automatic activation of Hired? The allowed answer is either: 0 (No: registration) or: 1 (Yes: pass to Hired).
0 = registration
1 = pass to Hired
The ForHire led flashes if IR-sensor is ON? - When the IR-sensor is activated should the ForHire led flash?
The allowed answer is either: 0 (No: don't flash) or: 1 (Yes: flash).
from Q 316 / Available for any possible software extension / to Q 318
STATISTICAL MEMORY BLOCK N.1
Inhibit visualization memory-block n. 1? - Should it be impossible to visualize memory-block number 1? See also Q.320.
The allowed answer is either: 0 (No: visualize) or: 1 (Yes: inhibit).
Enable visualization MB1 with password? - If the visualization of memory-block number 1 has been inhibited (see Q.319) should it be possible to undo this with the
password? The allowed answer is either: 0 (No: keep inhibited) or: 1 (Yes: enable with password).
Inhibit printing memory-block n. 1? - Should it be impossible to print memory-block number 1? See also Q.322.
The allowed answer is either: 0 (No: print) or: 1 (Yes: inhibit).
Enable printing MB1 with password? - If the printing of memory-block number 1 has been inhibited (see Q.321) should it be possible to undo this with the password?
The allowed answer is either: 0 (No: keep inhibited) or: 1 (Yes: enable with password).
Inhibit reset of memory-block n. 1? - Should it be impossible to reset memory-block number 1 from panel? See also Q.324.
The allowed answer is either: 0 (No: reset from panel) or: 1 (Yes: inhibit).
Enable reset of MB1 with password? - If the reset from panel of memory-block number 1 has been inhibited (see Q.323) should it be possible to undo this with the
password? The allowed answer is either: 0 (No: keep inhibited) or: 1 (Yes: enable with password).
Inhibit access to stat. Memory n. 1? - Should it be impossible to have access to the reading-procedure of the statistics-memory number 1?
The allowed answer is either: 0 (No: access) or: 1 (Yes: no access).
ACCESS TO TARIFF PROGRAMMING
Programming only with the memory-key? - Should programming only be possible with the memory-key? If not, then programming is also possible step by step. The
allowed answer is either: 0 (No: also step by step) or: 1 (Yes: only memory-key).
STATISTICAL MEMORY BLOCK N. 2
Inhibit visualization memory-block n. 2? - Should it be impossible to visualize memory-block number 2? See also Q.328.
The allowed answer is either: 0 (No: visualize) or: 1 (Yes: inhibit).