DigiTrak eclipse - User Manual

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
®
inGround Positioning System (iGPS
®
)
Operator’s Manual
DIGITAL
CONTROL
INCORPORATED
DCI Headquarters
19625 62
nd
Ave. S., Suite B-103
Kent, Washington 98032 USA
Tel 425 251 0559 / 800 288 3610 Fax 253 395 2800
E-mail DCI@digital-control.com www.digitrak.com
DCI Europe
Kurmainzer Strasse 56
D-97836 Bischbrunn
Germany
Tel +49(0) 9394 990 990
Fax +49(0) 9394 990 999
DCI.Europe@digital-control.com
DCI India
SCO # 259, Sector 44-C
Chandigarh (UT) 160 047
Punjab, India
Tel +91(0) 172 464 0444
Fax +91(0) 172 464 0999
DCI.India@digital-control.com
DCI China
USA Excalibre
2803 Bldg C, 70 Cao Bao Rd
Shanghai P.R.C. 200233
Tel +86(0) 21 6432 5186
Fax +86(0) 21 6432 5187
DCI.China@digital-control.com
DCI Australia
2/9 Frinton Street
Southport, Queensland 4215
Australia
Tel +61(0) 7 5531 4283
Fax +61(0) 7 5531 2617
DCI.Australia@digital-control.com
DCI Russia
420059 Pavlyukhina Street
104, Kazan
Russia
Tel +7 843 277 52 22
Fax +7 843 277 52 22
DCI.Russia@digital-control.com

Table of Contents

Questions and Answers

  • S
    Sarah PatrickSep 4, 2025
    What to do if DigiTrak Test Equipment depth is greater than expected?
    • J
      Jessica AtkinsSep 4, 2025
      If the depth reading on your DigiTrak Test Equipment is greater than expected, the receiver might be set to the wrong frequency. Exit to the main menu, change the frequency setting, and then return to the locate screen to take another depth reading.
  • M
    Melinda LewisSep 18, 2025
    Why DigiTrak Remote Display update indicator stops rotating?
    • E
      Erin WilliamsSep 18, 2025
      The receiver is not in locate mode and, therefore, is not sending data to the remote display. The receiver must be in locate mode to send signals to the remote display. Also, the remote may not be receiving information from the receiver, so try repositioning the receiver and/or the remote to reduce interference.
  • Y
    yjohnsonSep 16, 2025
    What to do if DigiTrak Remote Display loses data?
    • P
      Patrick HendersonSep 16, 2025
      Verify that the receiver and remote display are set to the same channel and that the Tele Option or TLT settings are correct. From the receiver, exit locate mode and then go back into locate mode.
  • M
    milescindySep 14, 2025
    What to do if DigiTrak Test Equipment shows “Recal Tilt” message?
    • K
      Kimberly SmallSep 14, 2025
      If your DigiTrak Test Equipment displays a “Recal Tilt” message dialog box, the receiver battery may be low. Select “N” for No in the dialog box and replace the battery. If you selected “Y” for Yes, call DCI Customer Service.
  • C
    Catherine CrossSep 12, 2025
    Why DigiTrak Test Equipment transmitter battery status icon does not display battery status?
    • J
      James GentrySep 12, 2025
      Turn the DigiTrak Test Equipment receiver off and then back on. Go back into locate mode and hold the trigger to view the transmitter battery icon with status bars inside. You can also try changing the transmitter’s battery.
  • L
    Leah VasquezSep 12, 2025
    Why DigiTrak Test Equipment pitch, roll, or depth information is different than on remote display?
    • T
      Thomas JonesSep 12, 2025
      The receiver and remote display may be set to different channels or using different measurement settings. Verify that both units are set to the same channel, grade mode, and depth measurement mode. If the problem persists with the same settings, try using a different channel.
  • D
    David CrawfordSep 9, 2025
    How to align DigiTrak Test Equipment LL with horizontal cross hairs?
    • L
      Lisa BentonSep 9, 2025
      Try lifting the DigiTrak Test Equipment receiver as high as possible. If holding the receiver higher doesn’t help, try taking a step either forward or backward. Then align the LL to the top or bottom of the Eclipse icon rather than the cross hair through the center of the icon.
  • M
    Mark KimSep 7, 2025
    How to fix DigiTrak Test Equipment LL display?
    • R
      richard70Sep 7, 2025
      Position the DigiTrak Test Equipment receiver over one of the two locate points and hold in the trigger for at least one second, then release the trigger. The reference “R” should display at the top of the locate screen and the LL should come up.
  • E
    Eric HamiltonSep 5, 2025
    What to do if DigiTrak Test Equipment pitch, roll, temperature, and/or transmitter battery status blinks?
    • C
      Carrie StewartSep 5, 2025
      If the pitch, roll, temperature, and/or transmitter battery status is blinking on your DigiTrak Test Equipment, move the receiver closer to the transmitter and away from potential interference sources.
  • M
    Matthew EdwardsAug 21, 2025
    Why does DigiTrak Test Equipment display lock up?
    • K
      Kenneth DaughertyAug 21, 2025
      If your DigiTrak Test Equipment display locks up or becomes erratic, the battery is likely dead. Replace it with a fully charged battery and click the trigger to power up the unit.

Summary

Safety Precautions and Warnings

Receiver

Calibration Procedures

Detailed steps for 1-point and 2-point calibration of the receiver.

Configuration Settings

How to adjust key settings like frequency, grade, depth units, and telemetry.

Remote Display

Transmitter

Locating

Locating Procedure

Step-by-step guide for locating the transmitter using the Eclipse system.

The Target Steering Function

Determining and Programming Target Depth

How to determine feasible target depth and program it into the receiver.

Using Target Steering

Positioning the receiver and using remote display for steering guidance.

Cable System

Troubleshooting

Receiver Issues

Common problems and solutions for the Eclipse receiver.

Remote Display Issues

Common problems and solutions for the Eclipse remote display.

DigiTrak eclipse Specifications

General IconGeneral
BrandDigiTrak
Modeleclipse
CategoryTest Equipment
LanguageEnglish