52
The descriptions of every setting in this menu will be given below:
Item Description
Network Type This camera can obtain the IP address from DHCP server
automatically (if you have one), or set a fixed IP address.
Select ‘DHCP’ to obtain IP address automatically or ‘Static IP
Address’ to assign this IP camera with a fixed IP address.
When ‘DHCP’ is selected, IP address parameters below will be
grayed out.
IP Address Specify the IP address for this IP camera here.
Subnet Mask Specify the subnet mask for this IP camera here.
Gateway Specify the gateway address of the local network here.
Primary DNS Specify the IP address of DNS server here. Please input IP
address only. If you don’t know the address of DNS server, ask
network administrator or your ISP for help.
Secondary DNS Specify the IP address of backup DNS server here. When
primary DNS is unreachable, IP camera will use the IP
address specified here as DNS server.
This field is optional.
Web Port Specify the port number of web management interface here. If
it’s not 80, you’ll have to add ‘:port’ after the IP address /
hostname of this IP camera.
For example, if the HTTP port number you specified here is 90
and the IP address of IP camera is 10.20.20.30, then you have
to input ‘http://10.20.20.30:90’
in the address bar of Internet explorer.
Enable PPPoE Select ‘Enable’ to activate PPPoE function of this IP camera,
select ‘Disable’ to disable it.
User Name Input the PPPoE username assigned by your ISP here.
Password Input the PPPoE password assigned by your ISP here.
MTU Input the MTU (Maximum Transmission Unit) given by your
ISP here. Ask your ISP if you don’t know what value you
should input here. Default value should work with most of ISPs
and will give you a nice network performance.
Click ‘Apply’ to save settings and make the new settings take effect.