Installation the Switch
Precautions: To avoid equipment damage and personal injury, observe the
following precautions:
The Switch room should be dry and ventilated, free from corrosive gases
and strong electromagnetic interference.
The humidity of the Switch equipment room should be lower than 90%
and around 25 degrees Celsius. If possible, install corresponding
facilities.
The grounding of the Switch shall comply with the grounding
requirements described in this manual, and shall be separately and well
grounded.
The Switch voltage should be stable to prevent abnormal operation of
the Switch caused by power supply voltage mutation, fluctuation and
other phenomena;
Keep a proper distance between the Switch and other devices. Do not
stack other devices with the Switch.
The connection cable between the Switch and the distribution frame
should be standardized and reasonable, and the distribution frame (box)
jumper wire should be concise and clear to prevent the phenomenon of
parallel lines and wires;
To avoid the danger of electric shock, do not open the chassis without
authorization; If any fault occurs, contact professional maintenance
personnel.
Safety Tips:
Use a three-hole socket with safe grounding, and ensure that the PGND
cable of the power socket is properly grounded.
Ensure sufficient space for heat dissipation and ventilation of the Switch.
Do not place heavy objects on the Switch.