Dimplex DC15RCBW - Water Drain Procedure (Error E4)

Dimplex DC15RCBW
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
OPERATION
NOTE: The outlet exhaust must still be attached to the window when using
the heating function. Return the outlet and tube to the rear of the unit for
cooling or dehumidication.
WATER DRAIN (Error Code E4)
When the air conditioner is used, excess water condensation may be
produced that cannot be removed via the exhaust hose. This water is
captured by an internal container. When this container is full, the unit
will stop working and display the E4 error code. When the error code is
displayed the water collected must be manually drained.
1. Switch off and unplug the unit.
2. Move the unit to a suitable place to drain the water. Consider placing
a tray or suitable container under the outlet pipe to catch the drained
water.
3. Remove the lower drain plug (11), refer to parts illustration.
4. Slightly tilt the unit to the rear to drain the water.
5. Replace the drain plug. Ensure the drain plug is re-tted to the drain
outlet before use.
NOTE: Extend the exhaust to the window before the unit is restarted.