13
Operation
Options
The Options Menu enables you to choose time and
temperature formats that suit your preferences.
These are:
DST Rule (Daylight Saving Setting) - None, UK/
Ireland, Canada & US
Temp Units - °C or °F
Setback Temp – Setback Temperature denes
the Comfort OFF temperature by the number
of degrees below the Comfort ON tempera-
ture. It ranges from 0°C (0°F) to 5°C (9°F).
It is highly recommended that a setback of
2°C (4°F) or less is used to reduce the time
the heater takes to bring the room back to its
Comfort On temperature. For example: If Set-
back temperature is 2°C and the comfort ON
temperature is set to 21°C, when the timer
mode switches to comfort OFF the heater will
regulate the room temperature at 19°C.
Child Lock
To lock the controls press back and the selector
dial together for 5 seconds. Child Lock will appear
at the bottom of the screen. To unlock the control
repeat the action of pressing back and selector
dial for 3 seconds.
!
NOTE: The controls cannot be adjusted when
the child lock is active.
User Information
Press and hold the selector dial for 5 seconds to
display the user information menu, three choices
are available:
SP Range - Adjustment of the temperature
range available
Factory - Returns all settings to the factory
presets – Yes or No.
Extra Charge - Adjustment to increase the
amount of energy stored
Service Menu
CAUTION: Changing the settings in the Ser-
vice Menu should ONLY be done by a SERVICE
TECHNICIAN as changes may affect the preferred
operation of the unit.
Press and hold the Menu, Back AND Selector dial
for 5 seconds to display the Service Menu, ve op-
tions are available:
1. Congure - has three options within it:
a. Initial Charge – Determines whether an
initial charge of 0% or 100% is needed.
b. Fan Speed - Adjustment of fan speed
between 75% and 100% mainly used to
reduce noise control.
!
NOTE: A lower maximum fan speed re-
sults in a lower maximum heater output.
c. Calibrate RTC (Real Time Clock) - Re-
boots the heater. The screen will light up
with no display during this process.
2. Appliance ID - Indicates you heaters unique
identication number.
3. Charge Time - Sets the standalone charge
time. When not connected to the Quantum
hub, this setting will be the core charging
time.
4. Heater Size - Displays the capacity of the
heater. The capacity of the heater can be
found on the rating label on the outer shell of
the heater.
!
NOTE: This setting should only be changed if
found to be incorrect.