EasyManua.ls Logo

Dimplex Revillusion RBF30 - Direct Power Wiring (240 V)

Dimplex Revillusion RBF30
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Direct Power Wiring (240 V)
All wiring must be completed prior to
installing the built-in electric firebox.
Use 3-conductor wires with ground
(4 wires total) from the power supply
(breaker panel) to the junction box on
the built-in electric firebox.
FIREPLACE JUNCTION BOX
WHITE - N
BLACK - L1
GROUND - G
WHITE - N
BLACK - L1
GROUND - G
240 V
POWER
SUPPLY
BREAKER
PANEL
RED - L2
RED - L2
BLUE - NH
To install 240 V direct power wiring:
1. Pull out the 5 wires marked L1, L2,
N, NH, and G (black, red, white,
blue, and green).
2. Connect N (white) from the built-in
electric firebox to the N (white) from
the power supply.
3. Terminate NH (blue) with a wire
connector (not included).
4. Connect L2 (red) wire from the
built-in electric firebox to the L2
(red) from the power supply.
Electrical
5. Connect L1 (black) wire from the
built-in electric firebox to the L1
(black) from the power supply.
6. Connect the G (green) ground wire
from the built-in electric firebox to
the ground from the power supply.
7. Insert all the wiring back into the
built-in electric firebox and secure
with a cable clamp.
8. Make sure all connections are tight.

Related product manuals