Problem Probable Cause(s) Suggested Remedies
__________________________________________________________________________________________
Perfect•Temp cart does Cart not connected properly.............Check that cart is properly connected
not rethermalize at all Controller circuit breakers
although controller tripped .............................................Reset circuit breakers on back of controller
appears to be Relays within controller
functioning properly defective..........................................Defective unit—return to factory
Refrigerator door left open ..............Close door
Refrigerator door switch
broken..............................................Fix switch
Cart circuit breaker(s)
tripped .............................................Reset circuit breaker on cart
_________________________________________________________________________________________
One side of Perfect• Controller circuit breaker tripped ....Reset circuit breakers on rear of controller
Temp cart does not All switches on that side of cart
rethermalize have been set to “cold”...................Reset correctly
Broker wire/connection within
cart at main power connection.......Inspect internal wire harness on cart
Defective relay contacts within
controller.........................................Return unit to factory for repair
Input power changed from 200-
240VAC to 120VAC......................Check power source
One cart circuit breaker tripped.......Reset circuit breaker on cart
_________________________________________________________________________________________
One specific shelf does Defective selector switch .................Replace switch
not rethermalize Broken wire/connection
within cart .......................................Inspect/repair wire/harness connection
_________________________________________________________________________________________
One specific heater pad Defective heater pad.........................Replace heater pad
does not rethermalize Bad electrical connection
between heater pad and
wire harness ...................................Check/correct wire connection
Improperly replaced heater pad
has damaged feed wires ................Inspect wires for signs of crimping or
damaged insulation
__________________________________________________________________________________________
For further equipment troubleshooting guidelines, please refer to the
Perfect•Temp Equipment Operation and Maintenance Manual.