EN
COMPACT
13
The interior cabin temperature is displayed when selecting this function.
Function
F1
-
Digital thermometer function
F2 programmes the unit for automatic disconnection in a period of 1 to 9 hours.
Programme by keeping the On/off
key pressed down until
F2
is displayed, then
select operation time using the
-
+
keys and conrm by pressing On/off .
Selecting
F4
allows the user to choose the comfort temperature 15ºC to 27ºC (59ºF
to 71ºF), which will be selected from the control panel
-
+
keys or the remote
control
keys. When selecting, the display will switch between
CA
and the
degrees selected. With this function the unit automatically regulates and controls comfort
temperature by acting on the compressors and fan speed. Pressing the
key on the
remote control cancels function
F4
and moves to
F0
(Manual Function).
To activate this function, keep the On/off
key pressed down until the display shows
F6
, and then release the key to directly enable ºF. To return to ºC, keep the control panel
-
key pressed down with the unit switched off, at which point
C
C
will flash; when it
stops flashing, press the
+
key on the control panel. The remote control is disabled
when carrying out this operation, meaning it must be registered once nished.
Function
F2
-
Time programming function
Function
F4
-
Automatic unit operation
Function
F6
- ºF Selection