TEMPERATURE CONTROL ADJUSTMENTS
Adjustment #1 - Temperature Adjustment
Turn the adjustment pointer clockwise for colder product and counter-clockwise for warmer
product.
Adjustment #2 - Altitude Adjustment
WARNING:
DISCONNECT POWER TO THE VENDING MACHINE BEFORE PROCEEDING
WITH THIS ADJUSTMENT.
The control is factory set for an altitude of 152 M (500 ft.). For higher altitudes, adjust the inside range
screws to prevent freeze-up of the product. Adjust the inside range screws as follows.
EATON 9531-N375 for 501E/600E
ALTITUDE EATON 9531-N387 for 276E
Meters Feet Turn both screws counter clockwise
610 2,000 1/8 Turn
1219 4,000 1/4 Turn
1829 6,000 1/2 Turn
2438 8,000 5/8 Turn