Page 75 of 72
SYMPTOM: EXCESSIVE CONDENSATE
WHAT TO CHECK SOLUTION
1. Is the door sealed properly?
(This can be checked by inserting a piece of paper, thin plastic, or
paper currency between the cabinet and the door seal when the
main door is open. When the door is closed properly the paper
should exert some resistance as it is pulled out.)
YES, go to step 4.
1. NO, Ensure the door is closed tightly. If door
still does not seal properly, see step 2.
2. Is the motor cover interfering with the inner door?
NO, go to step 3.
2. YES, reinstall the motor cover properly.
3. Has the machine been vandalized?
NO, go to step 4.
3. YES, replace necessary components.
4. Are the drain pan soakers positioned properly?
YES
4. NO, place soakers upright in pan so that air will
flow over and through the soakers..
5. Is the drain hose positioned properly?
YES
5. NO, place the drain hose in the drain pan along
side of the soakers. Ensure the drain hose is not
clogged.
6. Are there fourteen fiberglass soakers in the pan?
YES
6. NO, place fourteen fiberglass soakers in the
condensate pan.
7. Are the condensate & evaporator free from obstruction?
YES
7. NO, remove all debris and/or cans from the area
around the evaporator and condenser. Clean the
evaporator and condenser coils with a stiff brush
or compressed air.
8. Is the delivery door misaligned?
NO
8. YES,
A. Level the vender properly.
B. Align the inner and outer doors so that
the delivery door does not stick open.
9. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number available.
9. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number
available.