Set-up subject to change without notice. For packages not listed contact Dixie-Narco Factory
Service at (800) 688-9090. Page 38 of 72
DRIFTING MOTOR AND JACK-POTTING PROBLEM
SYMPTOM THINGS TO CHECK IF FAULTY, WHAT TO DO
1. The vend motor drifts:
Both switch arms drop into
the cam notch and the vend
motor keeps running.
A. Vend Motor Switch
B. Vend Motor Switch Arm
relationship to the cam.
C. Check the pawl for looseness.
It should be loose.
D. Pawl Spring.
E. Actuator should be loose.
A. Replace the switch.
B. If too close to the cam, bend the
arm away from the cam slightly
or replace the switch.
C. If tight, replace.
D. If off, correct. If elongated,
replace.
E. If actuator sticks to stator due to
syrup, clean stator. If tight,
clean at the pivot. If still tight,
replace the motor.
2. Two beverages delivered in
a cycle and the next cycle is
a dry vend.
A. Shimming.
B. Cam Setting.
A. Correct.
B. Correct.
3. Two beverages delivered in
a given cycle.
A. Shimming
B. Cam Setting.
C. Follow checking procedure
for a drifting motor.
A. Correct.
B. Correct.
C. Correct.
4. Pre-Select, i.e. set up credit,
push no button and product
is vended time after time.
A. Select Switch; Sticking,
incorrectly wired, or bad.
A. Replace or Correct.